15
PLA Series
PLA-RP60/71
100/125/140BA
(
i-see Sensor: optional
)
optional
4-way
Ce iling
Cassette
PLA Series
16
Advancements in PLA series improve style and
performance for ensured indoor comfort
Wide Airflow
Wide-angle outlets distribute airow to all corners
of the room, ensuring the room is suciently
cooled/heated. Horizontal airow and a fan speed
reduced by 20% compared to conventional
models also contribute to increased comfort for
occupants.
Conventional model
PLA-RP
] ]
BA
Less Cold Draft
The horizontal airow function prevents
cold drafts from striking the body directly,
thereby keeping the body from becoming
over-chilled.
Horizontal airow
prevents drafty feeling
Independent Vane Direction
Setting
Use the wired remote controller to set the
airow pattern of each vane independently.
Easily adjust airow to the interior layout
and seasonal conditions, to help ensure an
even temperature distribution.
Using wired remote controller,
set airow direction for each vane
(manual setting also possible)
]
Wired remote controller
(
PAR-31MAA
)
has Independent
Vane Direction Setting.
This function is only available
when indoor unit connects
with PUHZ series.
Settings can be changed anytime
using a wired remote controller.
Vertical
ow
Horizontal
ow
Set by remote
controller
Fixed
Temperature gap with uneven
temperature distribution
Temperature gap is decreased,
and room is warmed uniformly
Swing mode
Vertical ow
Wave Airflow Mode for Heating
The airow direction at each
outlet changes intermittent-
ly, providing a con
sistent
temperature through
out the
room.
Vertical
ow
Vertical
ow
Vertical
ow
Vertical
ow
Simultaneous horizontal and vertical operation ensure
a comfortable room from corner to corner.
“Wave Airow” operation image
• Wave control eect thermograph
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby helping to maintain a
comfortable room environment at all times. At the start of operation, a high
fan speed provides quick heating/cooling of the room. Once the desired
temperature is reached, the fan speed is reduced for stable heating/cooling
and greater comfort.
HiLo AutoMi2 Mi1
Fan speed setting by remote controller
(
four levels
)
]Special setting is required for wireless remote controller.
Quiet Operation
An improved airow path and powerful high-
capacity ow fan contribute to the realisation of
quieter operation.
Power ow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller present a
clean, streamlined image that is a suitable match for any interior.
Other Features
•
Stylish indoor-unit vane covers (when unit is turned o)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct ange for Fresh-air Intake
• Branch duct
Automatic Grille Lowering
Function
(
Option
)
Easy to use/Simple maintenance
An automatic grille lowering function capable of
stopping at eight dierent heights is available to
simplify lter maintenance.
Packaged elevating (up-down)
controller in the grille
(
PLP-6BAJ
)
can
be used when indoor unit connects
with PUHZ series and SUZ series.
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
four metres
4-way cassettes can be equipped with the i-see Sensor,
a radiation-based sensor that monitors oor-level
temperatures throughout the room to
ensure room comfort.
i-see Sensor works to
ensure even temperature
distribution and save
energy (requires optional
corner panel)
i-see Sensor improves energy efficiency and enhances room comfort (Option)
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a
radiation-based sensor to monitor temperature throughout the entire room. When
connected to the air conditioner control panel, i-see Sensor works to maximise
room comfort through 360° sensing that covers the whole oor space.
The i-see Sensor rotates 90° and takes 5-second
measurements to accurately determine oor-level
temperatures on all sides of the room.
■i-see Sensor Operation
• The i-see Sensor calculates the temperature by measuring the infrared rays emanating from
the walls and oors, and measuring the oor-level temperature.
• The sensor rotates 360° once every two minutes when there is signicant temperature
disparity and once every ve minutes when a stable, even temperature has been reached.
90°
rotation
90°
rotation
90°
rotation
5sec
measurement
5sec
measurement
5sec
measurement
5sec
measurement
360°
Floor-level temperature
measured throughout the room.
2.7m
Set temperature: 20°C
with i-see Sensor + Auto Fan Speed
Without i-see Sensor
With i-see Sensor
Area which the
“i-see Sensor”
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
Set temperature: 23°C
without i-see Sensor
37°C
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature and
the oor temperature. This technology helps to avoid overcooling or overheating.
sensing
11.5m
2.7m
sensing
11.5m
25°C
13°C
37°C
25°C
13°C
Heating Heating
2.7m
Area which the
i-see Sensor
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
360°360°
sensing
11.5m
2.7m
sensing
11.5m
Only intake-air temperature at the
ceiling is measured, resulting in
uneven temperature distribution.
Both oor-level and intake-air tempera-
tures are measured, providing operation
that creates a comfortable room envi-
ronment from ceiling to oor.
Wired remote controller
(
PAR-31MAA
)
has automatic grille
lowering function.
This function is only available
when indoor unit connects with
PUHZ series.
Elevating (up-down)
controller
Indoor unit
Specications: 4-way ceiling-cassette (PLA)
PLA-RP60BA
SUZ-K A60VAD
Cooling Heating
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
Power supply
Airow
(
Lo-Mi2-Mi1-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
* MEPS compliant at part load
* SUZ-K A
•
VAD is potentially demand response capable unit. DRC-101A is required.
CMM
PLA-RP71BA
12-14 -16-18 14-16-18-21
200-233-267-300 233-267-300-350
28-29-31-32 28-30-32-34
SUZ-K A71VAD
Cooling Heating
6.1 (2.3-6.3) 6.9 (2.5-8.0) 7.1 (2.8-8.1) 8.0 (2.6-10.2)
1.78 1.97 2.07 2.19
3.43 3.50 3.43 3.65
PLA-RP71BA
14-16-18-21
233-267-300-350
28-30-32-34
PUHZ-RP71VHA5
Cooling Heating
PLA-RP100BA
20-23-26-30
334-384-434-501
32-34-37-40
Unit: 25, Panel: 6
22-25-28-31
367- 417-467-517
34-36-39-41
Unit: 840, Panel: 950
Unit: 298, Panel: 35
Unit: 840, Panel: 950
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 27, Panel: 6
PUHZ-RP100V/YKA2
Cooling Heating
PLA-RP125BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Unit: 258, Panel: 35
Unit: 23, Panel: 6
PUHZ-RP125V/YKA2
Cooling Heating
PLA-RP140BA
PUHZ-RP140V/YKA2
Cooling Heating
13.0 (6.2-15.3)
3.97
3.27
16.0 (5.7-18.0)
4.43
3.61
12.5 (5.5-14.0)
3.80
3.29
14.0 (5.0-16.0)
3.71
3.77
10.0 (4.9-11.4)
2.50
4.00
11.2 (4.5-14.0)
2.95
3.80
2.09
3.40
2.17
7.1 (3. 3-8.1) 8.0 (3.5-10.2)
3.69
Rated AEER/ACOP
AEER/ACOP (part-load %)
]
3.36 3.44 3.38 3.60 3.10/3.08
3.95/3.89
3.44/3.423.10/3.08
4.13/4.05
3.56/3.543.67/3.63 3.54/3.503.22 3.49
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.