15
PLA Series
PLA-RP60/71
100/125/140BA
(
i-see Sensor: optional
)
optional
4-way
Ce iling
Cassette
PLA Series
16
Advancements in PLA series improve style and
performance for ensured indoor comfort
Wide Airflow
Wide-angle outlets distribute airow to all corners
of the room, ensuring the room is suciently
cooled/heated. Horizontal airow and a fan speed
reduced by 20% compared to conventional
models also contribute to increased comfort for
occupants.
Conventional model
PLA-RP
] ]
BA
Less Cold Draft
The horizontal airow function prevents
cold drafts from striking the body directly,
thereby keeping the body from becoming
over-chilled.
Horizontal airow
prevents drafty feeling
Independent Vane Direction
Setting
Use the wired remote controller to set the
airow pattern of each vane independently.
Easily adjust airow to the interior layout
and seasonal conditions, to help ensure an
even temperature distribution.
Using wired remote controller,
set airow direction for each vane
(manual setting also possible)
]
Wired remote controller
(
PAR-31MAA
)
has Independent
Vane Direction Setting.
This function is only available
when indoor unit connects
with PUHZ series.
Settings can be changed anytime
using a wired remote controller.
Vertical
ow
Horizontal
ow
Set by remote
controller
Fixed
Temperature gap with uneven
temperature distribution
Temperature gap is decreased,
and room is warmed uniformly
Swing mode
Vertical ow
Wave Airflow Mode for Heating
The airow direction at each
outlet changes intermittent-
ly, providing a con
sistent
temperature through
out the
room.
Vertical
ow
Vertical
ow
Vertical
ow
Vertical
ow
Simultaneous horizontal and vertical operation ensure
a comfortable room from corner to corner.
“Wave Airow” operation image
Wave control eect thermograph
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby helping to maintain a
comfortable room environment at all times. At the start of operation, a high
fan speed provides quick heating/cooling of the room. Once the desired
temperature is reached, the fan speed is reduced for stable heating/cooling
and greater comfort.
HiLo AutoMi2 Mi1
Fan speed setting by remote controller
(
four levels
)
]Special setting is required for wireless remote controller.
Quiet Operation
An improved airow path and powerful high-
capacity ow fan contribute to the realisation of
quieter operation.
Power ow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller present a
clean, streamlined image that is a suitable match for any interior.
Other Features
Stylish indoor-unit vane covers (when unit is turned o)
Maximum upward draining of 850mm
Wireless remote controller available
Duct ange for Fresh-air Intake
Branch duct
Automatic Grille Lowering
Function
(
Option
)
Easy to use/Simple maintenance
An automatic grille lowering function capable of
stopping at eight dierent heights is available to
simplify lter maintenance.
Packaged elevating (up-down)
controller in the grille
(
PLP-6BAJ
)
can
be used when indoor unit connects
with PUHZ series and SUZ series.
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
four metres
4-way cassettes can be equipped with the i-see Sensor,
a radiation-based sensor that monitors oor-level
temperatures throughout the room to
ensure room comfort.
i-see Sensor works to
ensure even temperature
distribution and save
energy (requires optional
corner panel)
i-see Sensor improves energy efficiency and enhances room comfort (Option)
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a
radiation-based sensor to monitor temperature throughout the entire room. When
connected to the air conditioner control panel, i-see Sensor works to maximise
room comfort through 360° sensing that covers the whole oor space.
The i-see Sensor rotates 90° and takes 5-second
measurements to accurately determine oor-level
temperatures on all sides of the room.
i-see Sensor Operation
The i-see Sensor calculates the temperature by measuring the infrared rays emanating from
the walls and oors, and measuring the oor-level temperature.
The sensor rotates 360° once every two minutes when there is signicant temperature
disparity and once every ve minutes when a stable, even temperature has been reached.
90°
rotation
90°
rotation
90°
rotation
5sec
measurement
5sec
measurement
5sec
measurement
5sec
measurement
360°
Floor-level temperature
measured throughout the room.
2.7m
Set temperature: 20°C
with i-see Sensor + Auto Fan Speed
Without i-see Sensor
With i-see Sensor
Area which the
i-see Sensor
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
Set temperature: 23°C
without i-see Sensor
37°C
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature and
the oor temperature. This technology helps to avoid overcooling or overheating.
sensing
11.5m
2.7m
sensing
11.5m
25°C
13°C
37°C
25°C
13°C
Heating Heating
2.7m
Area which the
i-see Sensor
checks
Indoor temperature
detecting sensor
Indoor temperature
detecting sensor
Area which the
sensor checks
3636
sensing
11.5m
2.7m
sensing
11.5m
Only intake-air temperature at the
ceiling is measured, resulting in
uneven temperature distribution.
Both oor-level and intake-air tempera-
tures are measured, providing operation
that creates a comfortable room envi-
ronment from ceiling to oor.
Wired remote controller
(
PAR-31MAA
)
has automatic grille
lowering function.
This function is only available
when indoor unit connects with
PUHZ series.
Elevating (up-down)
controller
Indoor unit
Specications: 4-way ceiling-cassette (PLA)
PLA-RP60BA
SUZ-K A60VAD
Cooling Heating
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
Power supply
Airow
(
Lo-Mi2-Mi1-Hi
)
Sound pressure level
Dimensions Width
Depth
Height
(
kW
)
(
kW
)
L/S
(
dB
)
(
kg
)
(mm)
(mm)
(mm)
Weight
* MEPS compliant at part load
* SUZ-K A
VAD is potentially demand response capable unit. DRC-101A is required.
CMM
PLA-RP71BA
12-14 -16-18 14-16-18-21
200-233-267-300 233-267-300-350
28-29-31-32 28-30-32-34
SUZ-K A71VAD
Cooling Heating
6.1 (2.3-6.3) 6.9 (2.5-8.0) 7.1 (2.8-8.1) 8.0 (2.6-10.2)
1.78 1.97 2.07 2.19
3.43 3.50 3.43 3.65
PLA-RP71BA
14-16-18-21
233-267-300-350
28-30-32-34
PUHZ-RP71VHA5
Cooling Heating
PLA-RP100BA
20-23-26-30
334-384-434-501
32-34-37-40
Unit: 25, Panel: 6
22-25-28-31
367- 417-467-517
34-36-39-41
Unit: 840, Panel: 950
Unit: 298, Panel: 35
Unit: 840, Panel: 950
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 27, Panel: 6
PUHZ-RP100V/YKA2
Cooling Heating
PLA-RP125BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
Unit: 258, Panel: 35
Unit: 23, Panel: 6
PUHZ-RP125V/YKA2
Cooling Heating
PLA-RP140BA
PUHZ-RP140V/YKA2
Cooling Heating
13.0 (6.2-15.3)
3.97
3.27
16.0 (5.7-18.0)
4.43
3.61
12.5 (5.5-14.0)
3.80
3.29
14.0 (5.0-16.0)
3.71
3.77
10.0 (4.9-11.4)
2.50
4.00
11.2 (4.5-14.0)
2.95
3.80
2.09
3.40
2.17
7.1 (3. 3-8.1) 8.0 (3.5-10.2)
3.69
Rated AEER/ACOP
AEER/ACOP (part-load %)
]
3.36 3.44 3.38 3.60 3.10/3.08
3.95/3.89
3.44/3.423.10/3.08
4.13/4.05
3.56/3.543.67/3.63 3.54/3.503.22 3.49
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Loading ...