49-80550-4
7
PRODUCT DIMENSIONS
Installation
Island Chimney Vent Hood
Instructions
* For supplied duct cover ceiling height for vented
installation and recirculating installation, refer to
the table on page 12.
µ
*Height to
ceiling
µ
µ
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT ³ Save these instructions
for local inspector’s use.
IMPORTANT ³ Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
for future reference.
Skill level – Installation of this vent hood requires
basic mechanical and electrical skills.
Completion time – Approximately
4 to 6 hours
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.
FOR YOUR SAFETY:
WARNING
Before beginning the installation,
switch power off at service panel and lock the
service disconnecting means to prevent power
from being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
CAUTION
Due to the weight and size of these
vent hoods and to reduce the risk of personal injury
or damage to the product,
TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
µ
INSTALLATION CLEARANCES
These vent hoods are
designed to be installed
onto a wall with no above
cabinets.
Install these hoods
between the required
24” minimum and
36” recommended
maximum above the
cooking surface.
The vent hood must be
installed between the
required 24” minimum
and 36” recommended maximum above the
cooking surface. The hood installation height
above the cooking surface depends upon ceiling
height and duct cover limitations. The telescopic
duct cover conceals the ductwork running from
the top of the hood to the ceiling.
NOTE: Installation height should be measured from
the cooking surface to the lowest part of the hood.
This hood must be installed onto a wall. It can be
vented to the outdoors, or it can be installed for
recirculating operation. Recirculating Kit included
with hood.
µ
24” Required Min.
36” Recommended Max.
36” Typical
*Height to Ceiling
Vented Recirculating
Min µ µ
Max µ µ