24
49-80550-4
STEP 9 CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with a
ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
Remove the 6 screws on the junction box cover
and the knockout on the top left side.
Secure the house wiring to the junction box with
a strain relief (not provided).
Connect the white lead to the branch circuit white lead.
Connect the black lead to the branch circuit black lead.
&RQQHFWWKHJUHHQ\HOORZOHDGWRWKHEUDQFK
circuit green lead or bare ground lead.
Secure all the connections with wire nuts on each
electrical connector.
Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
Secure the junction box cover with the 6 original
screws.
STEP 10
INSTALL DUCT COVER SUPPORTS
• Attach the duct cover supports to the sides of the
horizontal and ceiling supports using 4 screws per
duct cover support.
Junction
box cover
Knockout
Screws
Ceiling
support
Horizontal
support
Duct cover
support
Installation Preparation
,167$//$7,21³5(&,5&8/$7,1*