Electric Range installation manual Samsung NE59M4320SW/AC

Connecting the power

STEP 1. MEETING ELECTRICAL CONNECTION REQUIREMENTS

STEP 2. ACCESSING THE POWER CORD CONNECTION

Remove the rear access cover and loosen the screw with a screwdriver. The terminal block will then be accessible.

STEP 3. INSTALLING THE POWER CORD

For power cord installations, hook the strain relief over the power cord hole (13/8”) located below the rear of the drawer body. Insert the power cord through the strain relief and tighten the device

  • You must install the power cord with a strain relief.
  • Attach the strain relief to the 13/8” opening in conduit connection plate.

Installing a 3-wire power cord

WARNING: The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.

  1. Remove the 3 lower terminal screws from the terminal block.
  2. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block.
  3. Tighten screws securely into the terminal block. DO NOT remove the ground strap connection.
  4. Go to step 5 on page 10 and proceed with the installation.

Installing a 4-wire power cord

WARNING: The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.

  1. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.
  2. Cut and discard the ground strap. Do not discard any screws.
  3. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate, and into the frame of the range.
  4. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.
  5. Go to step 5 on page 10 and proceed with the installation.

STEP 4. INSTALLING THE CONDUIT

Remove the conduit connection plate from the rear of the drawer body and rotate it as shown below. The conduit hole (11/8”) must be used.

  1. Prepare the conduit cord shown in Figure 1.
  2. Install the conduit cord as shown in Figure 2

For conduit installations, insert the strain relief (not included) into the conduit hole (11/8”). Then thread the conduit cord through the body of the strain relief and fasten the ring. Reinstall the bracket.

Installing a 3-wire conduit

  • Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to Step 4 depending on the number of wires.
  • Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.
  1. Loosen the 3 lower terminal screws from the terminal block.
  2. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening.
  3. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
  4. Tighten the screws until the wire is firmly secured (35 to inch-lbs.). Do not over-tighten the screws since it could damage the wires.
  5. Go to step 5 on page 10 and proceed with the installation

Installing a 4-wire conduit

Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to this Step 4 depending on the number of wires.

Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.

  1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.
  2. Cut and discard the ground strap. Do not discard any screws.
  3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier).
  4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.
  5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
  6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires.
  7. Go to step 5 and proceed with the installation.

STEP 5. REPLACING THE ACCESS COVER



Newest Added: UN65TU8500FXZC SM-T875NZSAXSA SM-A715FZKUBTU QN49Q60RAFXZC QN49Q80TAFXZC

Also, These documents are for others Samsung models: NE59M4320SW

Tags: Samsung Fans Use Manual, Samsung Ne58k9850ws Installation Manual, SAMSUNG UE32T4300AKXXU, Samsung NE59M4320SW, Samsung NE58K9850WS, Samsung Oven NE59M4320SW, Samsung Ue32t4300akxxu Manual

Samsung NE59M4320SW/AC | File type: PDF | Filename: 35277591_ne59t7851ws-ac.pdf | Size: 2.6 MB | Language: English, French | Other documents: 1 files.

Download User Manual

Product Infomation and Reviews - NE59M4320SW/AC photo

NE59M4320SW AC Photo

Samsung in United States

1-800-726-7864 Mon - Fri: 8AM - 12AM (EST) / Sat - Sun: 9AM - 11PM (EST) Sat - Sun: HOME APPLIANCE 9AM - 6PM (EST)