13
7. General Error Function
- If the same signal as the above table is detected for more than
5 seconds, it is a PRESSURE S/W Error.
- When the error occurs, water drain pump will operate for 3 min. and
then turn off the water drain pump.
Then the display shows fig. 8 indicating a pressure s/w error indicator.
8. ABNORMAL WATER TEMPERATURE ERROR
- In case the water temperature is 50C or more in Delicate and Wool
course.
- At the time of initial water supply, if the water temperature is not
appropriate, water starts to be drained and it is forced to be drained
for 2 min when the abnormal frequency of 24.5KHz is detected.
- Display shows fig. 9
- This error can be cleared by POWER S/W OFF.
9. WATER LEAKAGE ERROR (E9)
- Water Leakage error occures when water is drained naturally after
washing program starts.
10. Tacho Error
- This error occurs in case motor thaco is out of order or tacho siganals
inputted are fewer than 2
- Display shows fig. 11
- This error can be cleared by power s/w off
11. Motor Triac short Error
- This error occurs in case over 300 per 1 sec tacho signals are inputted
power S/w should be off.
-fig. 12 is diplayed.
- This error can be cleared by power s/w off
12. Thermistor error
- This error occurs, when Thermistor circuit is abnormal or the detected
electrical volt is 0.2v below or 4.5v over
- fig. 13 is displayed
- This error can be cleared by power s/w off