A) Gas connection end
B) LPG pipe holder
Hob injectors replacement
Replace the injectors when you change the
gas type.
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. Remove the injectors with a socket
spanner 7.
4. Replace injectors with the ones
necessary for the type of gas you use.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply.
You can find this plate in the bag
supplied with the appliance.
If the supply gas pressure is not constant or
it is different from the necessary pressure,
install an applicable pressure adjuster on
the gas supply pipe.
Adjusting the minimum gas
level on the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there is
no access to the bypass screw
dismount the control panel before
adjustment start.
3. With a thin and flat screwdriver adjust
the bypass screw A.
The model determines the position of
the bypass screw A.
A
A
Changing from natural gas to
liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to
natural gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING!
Put the mains plug into the mains
socket only if all parts are back into
their initial position. There is a risk
of injury.
4. Light the burner.