A21
Controlling the Multiple Monitors
Command Reference List
COMMAND1 COMMAND2 DATA(Hexa)
01. Power k a 0, 1
02. Contrast k g 0 - 64
03. Brightness k h 0 - 64
04. Color k u 0, 2
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1]: First command.
* [Command 2]: Second command.
* [Set ID]: You can adjust the set ID to choose desired monitor
ID number in Setup menu. Adjustment range is
0~ 99. When selecting Set ID ‘0’, every connected
monitor set is controlled. Set ID is indicated as decimal
(0~99) on menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
* [DATA]: To transmit command data.
Transmit 'FF' data to read status of command.
* [Cr]: Carriage Return
ASCII code ‘0x0D’
* [ ]: ASCII code Space (0x20)’
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
Data 1: Illegal Code
2: Not supported function
3: Wait more time
Transmission / Receiving Protocol