GAS CONVERSION PROCEDURE
10. Re-fit oven supply pipe to burner and replace
the backpanel.
11. Place gas sticker supplied onto rear panel over
existing sticker.
12. Remove the regulator and replace with test point
adaptor supplied for ULP or propane. For NG
remove test point adaptor and replace with regulator
supplied. Note that ULP and propane both use the
same test point adaptor.
13. Turn on gas & check for leaks.
14. Check and adjust the test point pressure according
to the procedure in the installation instructions.
15. Light all burners and operate at maximum.
16. For each hotplate and grill burner adjust the burner
to minimum and screw in the bypass screw until
a small stable flame results. Adjust the burner to
maximum and back to minimum to ensure correct
adjustment.
17. Re-fit the control panel & re-connect to electrical
power.
1. Turn off gas supply to appliance.
2. Disconnect appliance from electrical power
(if applicable).
3. Pull off control knobs and remove control panel
(two screws).
4. Remove grill burner injector and replace with
appropriate injector.
5. Fit aeration control (shutter) supplied to grill burner
as required. See page 10 of instruction book for
grill shutter assembly diagram. Note that ULP and
propane use the same aeration control.
6. Remove existing hotplate injectors and fit appropriate
injectors supplied.
7. Remove by pass screw in oven thermostat and fit
appropriate by pass screw supplied. Note that ULP
and propane use the same by-pass screw.
8. Remove backpanel and disengage oven supply pipe
from oven burner.
9. Remove oven injector and replace with injector
supplied.
INJECTORS NATURAL GAS UNIVERSAL LPG PROPANE
Wok burner 1.75 mm 1.00 mm 0.95 mm
Large hotplate burner 1.60 mm 0.90 mm 0.95 mm
Medium hotplate burner 1.35 mm 0.70 mm 0.82 mm
Small hotplate burner 1.00 mm 0.55 mm 0.62 mm
Grill burner 1.50 mm 0.82 mm 0.82 mm
Oven burner 1.60 mm 0.82 mm 0.95 mm
Thermostat Bypass Screw 0.73 mm 0.45 mm 0.45 mm
Regulator NG Regulator
LP Test Point
Adaptor
LP Test Point
Adaptor
27GAS CONVERSION PROCEDURE