Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the + button when the fan is at setting
.
The intensive boost setting
is activated. Pressing the + button
again activates the intensive boost
ƒsetting.
After approx. six minutes, the electronics automatically reduce
the fan to a lower setting . If you want to end the intensive
setting before the preset time expires, press the - button until
the required fan setting is reached.
Fan run-on time
The fan run-on time is possible at every fan setting (except
boost
and boost ƒ).
Select the desired fan setting and press the
r button.
Šminr appears on the display.
Once this time has elapsed, the fan switches off automatically.
Setting the run-on time
When
Šminr appears on the display, press the + or - button.
You can set a run-on time of between 1 and 9 minutes.
Lighting
The lighting can be switched on and off independently of the
fan.
Press the
B button.
Setting the brightness
Press and hold the
B button until the desired brightness is
reached.
Saturation display
When the metal mesh grease filters or the activated carbon
filter are saturated, a signal sounds for approx. 4 seconds after
the fan is switched off.
In addition, the corresponding symbol appears in the display:
Metal mesh grease filter: #
Activated carbon filter: #
If you have not yet done so, the metal mesh grease filters
should be cleaned or the activated carbon filter changed now.
For instructions on how to clean the metal mesh grease filters,
please refer to the section Cleaning and maintenance.
While the saturation displays are flashing, they can be reset. To
do this, press the
# button.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display must be
switched over accordingly:
The extractor hood must be connected and switched off.
Press the % and r buttons at the same time until the
# display for starter sets for circulating-air mode or
# display for CleanAir circulating air modules
lights up.
Repeatedly press the button combination to switch the
electronic control display back to exhaust air mode (
#
display).
Audible signal
Switching on the acoustic signal
When the fan is switched off, press the
% and + buttons at the
same time for approx. three seconds. An acknowledgement
signal sounds.
Switching off the acoustic signal
Repeat the "Switching on the acoustic signal" process.
Control panel model 3
Control panel
Setting the fan
Switching on the appliance
Press the % button.
The fan starts at setting
ƒ.
Press the + or - button to change the fan strength.
Switching off
Press the
% button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the + button when the fan is at setting
.
The intensive boost setting
is activated. Pressing the + button
again activates the intensive boost
ƒsetting.
After approx. six minutes, the electronics automatically reduce
the fan to a lower setting . If you want to end the intensive
setting before the preset time expires, press the - button until
the required fan setting is reached.
Automatic mode
Switching on the appliance
Press the % button.
The fan starts at
ƒ setting.
Press the 1 button.
The optimum fan setting
, ƒ or is automatically set via a
sensor.
Switching off the appliance
Press the
1 or % button to switch off automatic mode.
The fan switches off automatically if the sensor no longer
detects a change in the air quality of the room.
The automatic mode lasts 4 hours at most.
Sensor control
In automatic mode, a sensor in the extractor hood detects the
intensity of the cooking and roasting fumes. Depending on the
setting of the sensor, the fan automatically switches to another
fan setting.
Default sensitivity setting:
Lowest sensitivity setting:
Highest sensitivity setting: Š
If the sensor control responds too quickly or too slowly, it can
be changed accordingly:
Explanation
%
Fan on/off
1
Eco function (automatic mode)
- Reduce the fan settings
+ Increase the fan settings/intensive setting 1, 2
r
Fan run-on time
B
Light on/off/dimming
HFR
ERRVW
HFR
Loading ...
Loading ...
Loading ...