Operation
These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Control panel model 1
Control panel
Setting the fan
Switching on the appliance
Press the % button.
The fan starts at setting
ƒ.
Press the + or - button to change the fan strength.
Switching off
Press the
% button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the + button when the fan is at setting
.
The intensive boost setting
is activated. Pressing the + button
again activates the intensive boost
ƒsetting.
After approx. six minutes, the electronics automatically reduce
the fan to a lower setting . If you want to end the intensive
setting before the preset time expires, press the - button until
the required fan setting is reached.
Fan run-on time
Press the - button until r appears.
After approx. ten minutes, the fan switches off automatically.
Lighting
The lighting can be switched on and off independently of the fan.
Press the B button.
Setting the brightness
Press and hold the
B button until the desired brightness is
reached.
Saturation display
When the metal mesh grease filters or the activated carbon
filter are saturated, a signal sounds for approx. 4 seconds after
the fan is switched off.
In addition, the corresponding symbol appears in the display:
Metal mesh grease filter: #
Activated carbon filter: #
If you have not yet done so, the metal mesh grease filters
should be cleaned or the activated carbon filter changed now.
For instructions on how to clean the metal mesh grease filters,
please refer to the section Cleaning and maintenance.
While the saturation displays are flashing, they can be reset. To
do this, press the – button.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display must be
switched over accordingly:
The extractor hood must be connected and switched off.
Press the % and buttons at the same time until the
# display for starter sets for circulating-air mode or
# display for CleanAir circulating air modules
lights up.
Repeatedly press the button combination to switch the
electronic control display back to exhaust air mode (
#
display).
Audible signal
Switching on the acoustic signal
When the fan is switched off, press the
% and + buttons at the
same time for approx. three seconds. An acknowledgement
signal sounds.
Switching off the acoustic signal
Repeat the "Switching on the acoustic signal" process.
Control panel model 2
Control panel
Setting the fan
Switching on the appliance
Press the % button.
The fan starts at setting
ƒ.
Press the + or - button to change the fan strength.
Switching off
Press the
% button.
Explanation
%
Fan on/off
- Reduce the fan settings/fan run-on time
+ Increase the fan settings/intensive setting 1, 2
B
Light on/off/dimming
ERRVW
Explanation
%
Fan on/off
#
Switch off the saturation display
- Reduce the fan settings
+ Increase the fan settings/intensive setting 1, 2
r
Fan run-on time
B
Light on/off/dimming
ERRVW