INSTALLATION INSTRUCTIONS
WARNING!
Failure to install the screws or
fixingdevice in accordance with
theseinstructions may result in
electricalhazards.
Installation
1
Preparing the rangehood for installation:
Before commencement, unpack
therangehood and check that it
functions correctly.
Ensure the overhead cabinets are built
according to the minimum clearances
table on page7.
Before drilling any holes, check that the
area behind the surface to be drilled is
clear of any electrical cables or pipes etc.
Ducted installation
(HS60LXW4, HS60XW4, HS90X4)
If the rangehood is to be installed as a
ducted hood:
Do not remove cover tape (A), See Fig.1.
This is removed for recirculating only.
Place adaptor in top extraction.
Place cover on rear extraction.
Front Recirculating installation
(HS60LXW4, HS60LRX4)
If the rangehood is to be installed as a
recirculating hood:
Remove cover tape (A), see Fig.1.
Place covers on rear and top extraction.
Install carbon filters see page12.
Assemble tall handle (70mm)
2
Mounting the rangehood
Mounting to underside of cupboard
Fix the rangehood to a shelf mounted
at the right height in your wall units,
by drilling 4 holes, 7 mm in diameter,
(see Fig.2) and fixing with the 4screws
supplied. When installing the rangehood
the space between the product and the
wall shall be covered with the adjustable
lateral and rear spacer supplied (Fig.3
and Fig.4).
Fig.2 Mounting to underside of cabinetry
FIG. 8
210 mm
35 mm
453/753 mm
Wall
209 mm
Ø125 - 130 mm
Fig.4 Spacer Rear
Screw shall be fixed into
lower face of the hood
FIG. 6
Fig.3 Spacer Lateral
FIG. 5
FIG. 4
A
Fig.1 Preparing for install