Possible Causes
Solution
The drying cycle has been
interrupted by a power failure.
Touch and hold START to restart the dryer. NOTE: The Control
Lock function may be enabled when recovering from a power
failure. To unlock the control, touch and hold CONTROL LOCK
for at least 3 seconds.
There may be a problem with your
home power supply, keeping the
dryer’s heater from turning on.
The dryer will continue to run when this diagnostic code is
present. Touch any pad to clear the code from the display
and return to the estimated time remaining.
NOTE: This error will only show during the initial installation.
Try the following:
Check to see if a household fuse has blown or circuit breaker
has tripped. Electric dryers use two household fuses or
breakers. Replace the fuse or reset the circuit breaker.
Conrm that the power cord is properly installed. Refer to
the Installation Instructions for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualied electrician.
“L2” Diagnostic Code
(low or no line voltage
condition)
The lint screen or vent is clogged;
the vent is crushed or kinked or
has too many turns.
The dryer will continue to run when this indicator is lit.
Try the following:
• Clean lint screen.
Check to see if the vent run from the dryer to the wall is
crushed or kinked.
Conrm that the vent run from the dryer to the wall is free
of lint and debris.
Conrm that the exterior vent exhaust hood is free of lint
and debris.
Conrm that your vent system falls within the recommended
run length and number of elbows for the type of vent you
are using. Refer to “Plan Vent System” in the Installaton
Instructions for details.
Select a Timed Dry heated cycle, and restart the dryer.
If the indicator remains lit, have your entire home venting run
cleaned.
Check Vent indicator is lit
“PF” (power failure)
The dryer is in need of service. If a code beginning with an “F” appears in the display,
alternating between F# and E#, the dryer control has
detected a problem that requires service. Call for service.
Dryer Displaying Code Message or Cycle Status Indicator Lights Up
Dryer Results (cont.)
Load removed before cooldown
portion of cycle complete.
Allow the dryer to complete the cooldown portion of the cycle
before removing the load.
Load too hot
Using Timed Dry cycle with a
high temperature setting.
Select an Automatic Cycle with a lower heat setting to avoid
overdrying the load.
Odors
Recent painting, staining, or
varnishing in the area where
your dryer is located.
Ventilate the area. When the odors or fumes are gone from
the area, rewash and dry the clothing.
Steam models only: For steam
cycles, the water is not properly
connected with the dryer.
Make sure water is connected to the dryer. Check that water
inlet hose is connected to both the faucet and dryer’s water
inlet valve. Check that the water supply is turned on.
Odors are left in garments after
wearing.
Steam models only: To remove odors left in garments after
wearing, select Steam Refresh. This cycle is best for reducing
wrinkles and odors from dry loads consisting of wrinkle-free
cotton, cotton-polyester blends, common knits, and synthetics.
“F# E#” (F1 E1, F3 E1, etc.)
variable service codes
First try the solutions suggested here or visit our website at www.whirlpool.com/product_help –
In Canada www.whirlpool.ca for assistance and to possibly avoid a service call.
If you experience
Troubleshooting
The Control Lock is enabled. Touch and hold CONTROL LOCK for 3 seconds to unlock
the controls of the dryer. During this time the LED Display
will count down 3-2-1. When the Control Lock is disabled,
the LED Display will clear.
“Loc” or “Lc”
Loading ...
Loading ...
Loading ...