User manual Dehumidifier

Controls
NOTE: When the bucket is full or removed, the controls cannot be set.
1. Power Pad
Press to turn the dehumidifier on and off.
2. Filter Timer
After 250 hours of operation, the Clean the Filter indicator light will glow to remind you to clean the filter. Remove the filter and clean it.
Press to turn off the Clean the Filter light. See the Care and Cleaning section.
3. Humidity Set Control Pads
pad until the screen reads NS.For drier air. press the
pad and set to a lower percent value (%).
For damper air. press the
pad and set to a higher percent value (%).
4. Display
Shows the set % humidity level while setting. then shows the actual (+/— 5% accuracy) room % humidity level.
5. Fan Speed Pad
Press to select either High. Medium or Low fan speed.
Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred. set the fan control to Medium or Low.
6. Delay Off
While the dehumidifier is in operation. press this pad to set ito automatically tum off in 2 hours or 4 hours.
7. Pump
Activates the intemal pump function. Press for 3 seconds to activate the intemal pump for automatic removal of condensate. The internal pump indicator light wil remain iluminated after 3 seconds. Press to deactivate the pump.
Empty Light
Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position.
Alarm
If the bucket is full or missing for more than 3 minutes, an alarm will sound for about 10 seconds to remind you to empty and replace the bucket.
Auto Shut Off
The Water Lever Control Switch shuts off the dehumidifier when the bucket is full, or when the bucket is removed or not replaced in the proper position. NOTE: Fan will continue to run approximately 3 minutes after bucket is removed.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will automatically restart, in the settings last used, after the power is restored.
When first using the dehumidifier, operate the unit continuously for 24 hours.
How the Dehumidifier Operates
Automatic Defrost
Choosing a Location
A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
NOTE: The dehumidifier has rollers to aid placement, but it should only be rolled on smooth, flat surfaces. Do not attempt to roll the dehumidifier on carpet or over objects.

Removing Collected Water

IMPORTANT: Do not use the hose if using the bucket to collect water. When the hose is connected, water will flow through it onto the floor instead of into the bucket.

NOTES
Use a hose. Water can be automatically emptied into a floor drain by attaching a garden water hose (not included).

1. Remove the bucket from the front of the unit.
2. Open the drain cover on the back of the unit.

3. Thread a garden hose ( not supplied) onto the nozzle, cut to length, and lead it to the floor drain.

4. Replace the bucket in the unit.
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.
Use the internal pump. Water can be automatically emptied into a remote location by attaching the included pump hose.
IMPORTANT: Make sure the condensate hose is properly connected and is not kinked, bent or cracked as this may cause water to flow onto the floor. The bucket must also be flly seated for the pump to work properly. Do not operate the machine if the room temperature is 32°F or below.
NOTES:
Make sure to install hose (included) before activating the pump

To Install Hose: Push in hose and gently pull to make sure it is secure.

To Release Hose: Hold the grey ring while pulling to remove.

NOTE: DO NOT kink or crimp hose, as it can block water flow.
Water Level
Bucket Operation

Turn off the dehumidifier and remove the plug from the wall outlet before cleaning.
To clean the case:
Use water and a mild detergent. Do not use bleach or abrasives.
To clean the front grille:
Use a vacuum attachment or brush.
To clean:
Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty and rinse.
NOTE: Do not use a dishwasher to clean the water bucket.
To remove:
Remove the bucket and pour out any water.
To replace:
Slide the bucket into the dehumidifier.
NOTE: The bucket must be in place and securely seated for the dehumidifier to operate.

To remove:
To clean:
NOTE: DO NOT rinse or put the filter in an automatic dishwasher.

NOTE: Avoid using a dishwasher to clean the filter
The bucket itis located inside the bucket near the bottom. The fiter should be checked when cleaning the bucket. If the filter has any debris on it, gently remove the filter as described below and rinse with warm water. Replace the filter in the bucket once it is clean.

MPORTANT: Be careful not to tear or damage filter during removal, cleaning or replacement. Do not use the dishwasher to clean the filter.
1. Lift the handle to make the ends of the handle align with the holes in the clasps. Push the handle towards one of the clasps keeping the handle aligned with the clasp slots. Push the other clasp away from the handle allowing the handle to be separated from the clasp. Remove the handle from the other clasp.

2. Squeeze both clasp inward to disengage clasp clips from water tank cover. Lift the cover upwards to remove.

3. Lift the end of the filter upwards to remove the filter

TO REPLACE THE FILTER:
4. Place large end of filter above tabs, press filter down firmly to spread tabs. Once filter is between tabs press filter inward to engage tabs into filter.
5. Replace water tank cover and handle.
If the unit is to be stored for an extended period of time. take the following actions before putting away the machine.
To Release Hose: Hold the grey ring while pulling the hose to remove.

Dehumidifier does not start
Makes sure the dehumidifier’s plug is pushed completely into the outlet.
Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
The dehumidifier automatically turn off when either condition occurs. Change to a lower setting or empty
the bucket and replace properly.
The bucket must be in place and securely seated for the dehumidifier to operate.
There is a protective time delay ( up to 3 minutes) to prevent tripping of the compressor overload. For this
reason, the unit may not start normal heating or cooling for 3 minutes after it turned back on.
Dehumidifier does not dry the air as it should
When first installed, allow at least 24 hours to maintain the desired dryness.
Make sure there are no curtains, blinds or furniture blocking the front of back of the dehumidifier. See the Choosing a Location section.
See the Care and Cleaning section.
For drier air, press the + pad and set to a lower percent value (%) or at NS ( Nonstop) for maximum dehumidification.
Check that all doors, windows and other openings are securely closed.
Install the dehumidifier away from the dyer. The dryer should be vented to the outside.
Moisture removal is best at higher room temperatures. Lower room temperatures will reduce the moisture removal rate. Models are designed to be operated at temperatures above 41°F (5°C).
Dehumidifier runs too much
The capacity of your dehumidifier may not be adequate.
Close all doors and windows to the outside
Frost appears on the coils
This is normal. Frost will usually disappear within 60 minutes. See the Automatic Defrost section.
Control cannot be set
This is normal. Wait approximately 3 minutes and set the fan as desired.
Fan noise
This is normal.
Water on floor
Check the hose connection. See the Removing Collected Water section.
Disconnect the hose if using a bucket to collect water. See the Removing Collected Water section.
Bucket Full LED light flashing and alarm sounds while drain hose is connected.
Check drain hose connection
Ensure the drain hose is pointed straight down to the floor and is not kinked in anyway