SECTION 5 SERVICE TECH. INFORMATION
5A. TROUBLESHOOTING
Keep this manual with your water softener. If repairs are needed, the service technician must have
the information on the following pages. For telephone assistance, call toll free, 1-800-426-9345.
TRANSFORMER
24VAC
VAC
WIRING SCHEMATIC
wh
NC
O'_ POSITION SWITCH
O
NO
r
Display
{ }
ON/OFF - HOLD button
(RECHARGE TONIGHT - NOW)
DOWN
UP button button
Kenmor_
SELECT button
k_kte_ kn_
Wl_Dmmm4__
,J
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. I)oes the tilne (lisl?lay show the Colwect time of day?
2o
3.
4.
5.
- If display is [)lank, check power source to the
softener.
- If time is flashing, power was offfor over 6 hours. The
softener resurnes normal operation but regenerations
occur at the wrong tirne.
- If an error code (Example: En 03) shows in the time
plate display, go to A[ TOMATIC ELECTRONIC I)IAG-
NOSTICS.
Plumbing bypass valve(s) must be in Full Service
position.
The inlet an(] outlet pipes InLIStCoilnec[ tOtile softener
valve inlet and outlet respectively.
IS tile transforlller plugged into a "live", grounded wall
outlet, and is the po\\er cable fastened securely?
The xalve (]rain hose InklSt De free ()f kinks and sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6. Is there salt in the storage tank?
7. Is the brine tubing connected? (See water flo\_
diagrams).
8. Is the brine xalve float set right? (See page 22).
°
Press the SELEC£ button 2 times to display fl:e hardness
setting. Be sure it is the correct setting for the
household's water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press SELE(71' twice more to return the time of day
display.
If you do not find the problem after inaking initial checks,
do tile M)U\q :2,tLINITIATEI) ELECIt\O: ,IC I)IAGNOSTICS,
and the MAN[ AL AI)VANCE REGENERATION CItECK.