Loading ...
Loading ...
Loading ...
42 English
Maintenance
Maintenance
Pump lter
It is advisable to clean the pump lter 5 or 6 times a year to prevent its clogging. A clogged
pump lter may reduce the bubble effect.
A
1. Turn off the washing machine, and
unplug the power cord.
2. Drain the remaining water inside the
drum drum. See the “Emergency drain”
section.
3. Open the lter cover using a coin or key.
4. Turn the pump lter knob to the left, and
drain off the remaining water.
5. Clean the pump lter using soft brushes.
Make sure the drain pump propeller
inside the lter is unclogged.
6. Reinsert the pump lter, and turn the
lter knob to the right.
NOTE
• Some pump lters feature a safety knob
that is designed to prevent accidents
by children. To open the safety knob
of the pump lter, push in and turn it
anticlockwise. The spring mechanism of
the safety knob helps open the lter.
• To close the safety knob of the pump
lter, turn it clockwise. The spring makes
a rattling sound, which is normal.
NOTE
If the pump lter is clogged, an information code of “5C” appears on the screen.
CAUTION
• Make sure the lter knob is closed properly after cleaning the lter. Otherwise, this may
cause a leak.
• Make sure the lter is inserted properly after cleaning it. Otherwise, this may cause an
operational failure or a leak.
WW85K6410QX_DC68-03676K_EN.indd 42 2016/1/27 15:34:43
Loading ...
Loading ...
Loading ...