Installation
74
When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood
2 Extraction without a hood
A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window-
mounted extractor fan
D Directly outdoors through wall
Air
Combustion products
Extractor fan
5.2 Adaptation to different types of
gas
The appliance is preset for natural gas G20
at a pressure of 20 mbar. In case of
operation with other types of gas, the
burner nozzle must be changed and the
gas tap adjusted.
Replacing the nozzle
1. Open the door.
2. Completely remove all accessories from
inside the oven.
3. Lift up the oven surface and pull it
outwards.
4. Loosen the screws A and B.
5. Move away the lock that secures the
thermocouple and igniter to the burner
with screw A.