Installation
61
EN
5 Installation
5.1 Safety instructions
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (>90°C), otherwise they might
warp over time.
The minimum clearance between a
ventilation hood and the cooking surface
must be at least the distance indicated in the
ventilation hood installation instructions.
The minimum clearances must also be
respected for the edges of the hob on the
back as indicated in the mounting
illustrations.
5.2 Section cut from the countertop
Make a hole in the countertop of the unit
according to the dimensions shown in the
figure (mm).
Hobs with a frame
Heat production during appliance
operation
Risk of fire
Check that the carcase material is heat
resistant.
Check that the carcase has the required
openings.
CAUTION: The surface temperature
exceeds 95°C. To avoid a hazard,
under bench access must be restricted.
The following operation requires
building and/or carpentry work
and must therefore be carried out
by a competent tradesman.
Installation can be carried out on
various materials such as masonry,
metal, solid wood or plastic
laminated wood as long as they
are heat resistant (>90°C).
L X Y
570 560 500
760 750 500
A B C D E
min.
50
min.
460
min.
750
20-60
min.
50