Loading ...
Loading ...
Loading ...
8
TOOL AIR FITTINGS:
This tool uses a 3/8" N.P.T. male plug. The in-
side diameter should be .39" (9.9mm) or larger.
The fitting must be capable of discharging tool air
pressure when disconnected from the air supply.
RECOMMENDED OPERATING PRES-
SURE:
70 to 100 p.s.i. (5 to 7 bar). Select the operating
air pressure within this range for best fastener
performance.
DO NOT EXCEED 120 p.s.i. (8 bar).
4. TECHNICAL DATA
1 NOISE
A-weighted single-event sound power level
------ LWA, 1s, d 101.03 dB
(SN883RH3, SN883CH2/28)
------ LWA, 1s, d 96.9 dB
(SN890CH3/34)
A-weighted single-event emission sound
pressure level at work station
------ LpA, 1s, d 92.72 dB
(SN883RH3, SN883CH2/28)
------ LpA, 1s, d 86.5 dB
(SN890CH3/34)
These values are determined and docu-
mented in accordance to EN12549 : 1999.
2 VIBRATION
Vibration characteristic value
= 4.26 m/s
2
(SN883RH3)
= 4.5 m/s
2
(SN890CH3/34)
= 3.84 m/s
2
(SN883CH2/28)
These values are determined and document-
ed in accordance to ISO 8662-11.
This value is a tool-related characteristic val-
ue and does not represent the influence to the
hand-arm-system when using the tool. An in-
fluence to the hand-arm-system when using
the tool will for example depend on the grip-
ping force, the contact pressure force, the
working direction, the adjustment of mains
supply, the workpiece, the workpiece support.
The above vibration measurement were re-
corded with the Black Trigger.
5. APPLICATIONS
Floor and wall framing
Subflooring
Roof and wall sheathing
Fencing