INSTALLING THE STAINLESS STEEL HANDLE
This appliance includes a stainless steel handle that is not required
to operate the unit. To install the handle, follow the instructions
below:
1. Remove the door gasket
2 on the side you wish to install the
handle - you can see two designated holes for handle
installation.
2. Install the handle
4 tightly as shown here with two screws
1
and flat washers
3 provided.
3. Replace the door gasket.
OPERATING YOUR APPLIANCE
It is recommended that you install the appliance in a place where the ambient temperature is between 7
and 78ºF (23º-26ºC). If the ambient temperature is above or below the recommended temperatures, the
performance of the unit may be affected. For example, placing your unit in extremely cold or hot
conditions may cause interior temperatures to fluctuate. The operating temperature range may not be
reached.
CONTROL PANEL
ON/OFF Power
To turn the appliance ON or OFF, press the symbol and hold for 5 seconds.
NOTE: Pressing this POWER key once can switch off the audible alarm when the alarm is on.
UP
Used to increase (warm) the set temperature by 1°C/1ºF.
DOWN
Used to decrease (cool) the set temperature by 1°C/1ºF.
Interior Light
The interior light makes it easy to view your items. Touching the LIGHT symbol toggles between 2
modes of operation for the internal light: functional (default) mode and showcase mode. If you are
Loading ...