Loading ...
Loading ...
Loading ...
12
MODES OF OPERATION
AUTO MODE OPERATION
When you set the air conditioner in AUTO mode, it will automatically select cooling, heating, or fan only operation
depending on what temperature you have selected and the room temperature. The indoor unit has a preset temper-
ature of 76°F when AUTO mode is initially started.
If the room temperature is 1°F(2°C) higher than the set temperature, the air conditioner will run in Cool mode.
If the room temperature is 1°F(2°C) lower than the set temperature, the air conditioner will run in Heat mode.
If the room temperature is 1°F(2°C) within the set temperature, the air conditioner will run in Fan mode.
NOTE: The fan speed is automatically selected and cannot be changed
COOL MODE OPERATION
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE
button on the remote control until the COOL indicator display comes on. When the cooling mode is set, the com-
pressor will start in approximately 3 minutes.
The cooling temperature setting range of this air conditioner is from 62°F-90°F or 17°C-32°C. To set the tempera-
ture, press the UP and DOWN buttons. This air conditioner has a 5°F temperature cushion which if the set tempera-
ture is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the
life of the compressor of the air conditioner.
To set the fan speed, press the FAN button. In cooling mode, the difference in noise level between the 3 fan speeds
is not very noticeable. Try setting the unit to Fan only mode, you should be able to hear the difference between high
and low fan speed settings.
DRY MODE OPERATION
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on
the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button
on the remote control until the DRY indicator display comes on. Please note that when switching function mode,
there will be an approximately 3 minute transition time.
NOTE: Fan speed is defaulted to AUTO and cannot be changed in Dry Mode.
FAN MODE OPERATION
In this mode, the outdoor unit is deactivated and only the indoor unit’s fan runs without any cooling or heating effect.
To activate this function mode, press the MODE button on the remote control until the FAN indicator display comes
on. Temperature setting buttons are deactivated. However, fan speed can still be adjusted as desired.
HEAT MODE OPERATION
This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat
to the indoor unit. In this mode, the air conditioner heats the room. To activate this function mode, press the MODE
button on the remote control until the HEAT indicator display comes on. When the heating mode is set, the compres-
sor will start in approximately 3-5 minutes.
The heating temperature setting range of this air conditioner is from 32°F - 86°F / 0°C - 30°C . To set the tempera-
ture, press the UP and DOWN buttons.
To set the fan speed, press the FAN button. In heating mode, the difference in noise level between the 3 fan speeds
is not very noticeable. Try setting the unit to Fan only mode, you should be able to hear the difference between high
and low fan speed settings.
TIMER ON SETTING
With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time
delay ON hours by pressing the UP and DOWN buttons. The time increments are at 0.5 hour to up to 10 hours, fol-
lowed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To
cancel the delayed switch on function, turn on the air conditioner or adjust the time setting to 0.0.
TIMER OFF SETTING
With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on.
Then set the desired time delay OFF hours by pressing the UP and DOWN buttons. The time increments are at 0.5
hour to up to 10 hours, followed by 1 hour increment up to 24 hours.