8 49-2000857 Rev. 0
Save time and money! Review the charts on the following pages first and you may not need to call for service.
TROUBLESHOOTING
Problem Possible Causes What To Do
Fan and lights do not operate when
the switches are turned on
The hood was never electrically
connected by the installer/ electrician/
builder.
Call the electrician/installer/builder to complete the
the installation. This is not covered by warranty.
A fuse may be blown or a circuit breaker
tripped.
Replace the fuse or reset the circuit breaker.
The blower does not work but the
lights do
The blower motor wire harness was
not connected or was not connected
properly by the installer/electrician/
builder to its mating connector located
inside the hood on the top surface, to
the left of the blower assembly.
6ZLWFKSRZHURႇDWVHUYLFHSDQHODQGORFNWKH
service disconnecting means to prevent power
from being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
5HPRYHWKH¿OWHUVDQGORFDWHWKHEORZHUZLUH
harness connector. Is it plugged into its mating
connector?
3. If no, plug the blower motor connector into its
mating connector on the top of the hood. Switch
the power back on. Check to see if the fan now
works.
4. If no, check the circuit breaker/fuse. If it is
blown/tripped, replace/reset it. Does the blower
work now? If no, call Monogram for service.
The blower fails to exhaust the
smoke/steam/odors adequately
Many factors could be the root cause for
UHGXFHGDLUÀRZ
Installation could be the problem: Your
KRRGZDVGHVLJQHGWRPHHWVSHFL¿F
ducting requirements. If your duct
length exceeds the manufacturers
requirements, hood performance will
VXႇHU$LUÀRZZLOODOVREHUHGXFHGLIWKH
house duct work is too small or there are
too many elbows in the system.
Contact your installer or builder.
Obstruction in duct work could be the
problem.
Make sure nothing is blocking the vent (bird nests
or kinks in the duct work).
Damper blade may not be opening.
Make sure the tape is removed from the damper
blades and that it swings open freely.
Damper blade on Wall or Roof Cap may
not be opening.
Contact your builder so they can make sure the
damper swings open freely.
'LUW\¿OWHUVEDႉHV 0DNHVXUH¿OWHUVDQGDOOKRRGVXUIDFHVDUHNHSW
clean of grease and dirt.
&KHFNWREHVXUHWKH¿OWHULVFOHDQ ,IUHSODFLQJWKH¿OWHUGRHVQRWFRUUHFWWKHSUREOHP
call for service.
6XႈFLHQWPDNHXSUHSODFHPHQWDLULV
required for exhausting appliances to
operate to rating.
Check with local building codes, which may
require or strongly advise the use of makeup air.
Visit Monogram.com for available makeup air
solutions.