Installation Instructions
ADJUST THE OVEN BURNER AIR
SHUTTER IF NECESSARY (CONT.)
6
For LP Gas:
The flame should have approximately 1-inch blue cones.
After 30 seconds of burner operation, check for flames
lifting off the burner parts. If lifting is observed, gradually
reduce the air shutter opening until flames are stabilized.
Some yellow tipping may be normal for LP gas.
If Adjustment is Necessary:
Loosen the lock screw located at the top of the air
shutter, then rotate the air shutter to the correct
setting and retighten screw.
QUALITY OF FLAMES
7
A
The oven burner air shutter adjustment is the same
on ranges with a gas pilot or electric ignition.
The air shutter should be set approximately 2/3
open for natural gas, and approximately full open
for LP gas.
Oven burner flame can be checked as follows
(without burner baffle in place):
• To correct a yellow flame—Increase size of air
shutter opening.
• To correct a lifting, but distinct, blue flame—
Decrease size of air shutter opening.
B
C
D
The combustion quality of burner flames needs to be
determined visually.
If burner flames look like (A), call for service. Normal
burner flames should look like (B) or (C), depending on
the type of gas you use.
With LP gas, some yellow tipping on outer cones is
normal.
(C) Soft blue flames:
Normal for natural gas.
(B) Yellow tips on outer cones:
Normal for LP gas.
(A) Yellow flames:
Call for service.
REPLACE OVEN PARTS
8
After all adjustments are made, replace the oven
bottom, shelves and oven door.
26
Loading ...
Loading ...
Loading ...