Cylinder Connecon: Ensure the gas regulator hose is kink free. Remove the cap or plug from the cylinder
fuel valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand ghten clockwise. Do
not use tools. Leak test all joints prior to using the grill. A leak test must be performed annually and each
me a cylinder is hooked up or if a part of the gas system is replaced.
If this grill is to be connected directly to a house propane gas supply line, follow the instrucons for the
natural gas hook-up. Oponal side burners must also follow the natural gas hook-up instrucons.
Note: The propane tank heat shield is not required when the grill is connected to a xed fuel supply, as its
sole funcon is to shield the propane tank normally used with the grill. Ensure that the supply pressure is
11 inches water column.
Natural Gas Hook-Up: These connecons must be made by a licensed gas er. This natural gas grill
is supplied with a gas supply hose (complete with a quick disconnect) designed for natural gas and
cered for out
door use. The gas grill is designed to operate at an inlet pressure of 7 inches water
column. Piping and valves upstream of the quick disconnect are not supplied. The installaon must
comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the Naonal Fuel Gas
Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to supply the BTU/h
specied on the rang plate, based on the length of the piping run.
The quick disconnect must not be installed in an upward direcon and a readily accessible manual shut-o
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end
of the
hose must be connected to the ng on the end of the manifold tube or ex tube (if applicable) as
illus
trated in the Natural Gas Hose Aachment diagram. Tighten using two wrenches. (Do not use thread
sealer/pipe dope.) Leak test all joints prior to using the gas grill.
WARNING!
• The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the grill.
• Do not route hose underneath the drip pan.
• Do not route hose between boom shelf space and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe
dope on any hose connecon.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
• Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons
found in the manual.
• The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the
gas
supply piping system during any pressure tesng of that system at test pressures in excess of 0.5 psi
(3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by
closing its individual manual shuto valve during any pressure tesng of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
!