18
Before you call for service...
Abnormal Operation
Model: CW-C84GU
Problem Possible Causes What To Do
■ The air conditioner is
unplugged.
■ The fuse is blown/circuit
breaker is tripped.
■ Power failure.
■ Airflow is restricted.
■ The THERMOSTAT may
not be set high enough.
■ The air filter is dirty.
■ The room may have been
hot.
■ Cold air is escaping.
■ Cooling coils have iced up.
■ Ice blocks the air flow and
stops the air conditioner
from cooling the room.
• Make sure the air conditioner plug is inserted
completely into the outlet.
• Check the house fuse/circuit breaker box and
replace the fuse or reset the breaker.
• If power failure occurs, turn the mode control to Off.
When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor
overload.
• Make sure there are no curtains, blinds, or furniture
blocking the front of the air conditioner.
• Turn the knob to a higher number. The highest
setting provides maximum cooling.
• Clean the filter at least every 2 weeks.
See the care and Maintenance section.
• When the air conditioner is first turned on, you need
to allow time for the room to cool down.
• Check for open furnace floor registers and cold air
returns.
• See Air Conditioner Freezing Up below.
• Set the mode control at Med Fan or High Cool with
thermostat at 1 or 2.
Air conditioner
does not start
Air conditioner
does not cool as it
should
Air conditioner
freezing up