Electrical Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at tile point the armored cable enters the
junction box. Then make the electrical connection as
follows.
Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor flexible came. Jf connection is
made to aluminum house wiring, use on[y specia[
connectors which are approved for joining cooper
and aluminum wires in accordance with the
National EJectrica[ Code and toca[ codes and
ordinances. Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Follow the connector manufacturer
recommended procedure closely.
This appliance is manufactured with a frame connected
green (or bare copper) ground wire.
DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until
app[iance is permanentJy grounded. Connect the
ground wire before turning on the power.
Where local codes permit connecting the appliance-
grounding conductor to the neutra[ (white} wire:
tf your cooktop has a 3-wire cable to be connected
to a 3-wire grounded junction box (see figure 4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 4.
Cable from Power Supply
Wh ite Wire
(Neutral)
\
Wires
Black
Wires
Box
Ground Wire U,L,-Listed Conduit
(Bare or Green Wire) Connector (or CSA
listed)
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
If your cooktop has a 4-wire cable to be connected
to a 3-wire grounded iunction box (see figure 5):
1. Disconnect tile power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 5.
Cable from Power Supply
White Wire
(Neutral)
Red
Wires
Wires -
Box
(Neutral)
Ground Wire U,L,-Listed Conduit
(Bare or Green Wire) ]onnector (or CSA listed)
Cable from appliance
Figure 5
3-WIRE GROUNDED JUNCTION BOX
36" Models with Warmer Zone
You may not ground the cooktop
through the neutral (white} wire if cooktop is used
in a new branch circuit installation (1996 NEC),
mobile home, recreationaJ vehicle, or where iota[
codes do not permit grounding through the
neutra[ (white} wire. When grounding through the
neutra[ (white} wire is prohibited, you must use a
4-wire power supply cable. See Figure 6 & 7.
Failure to heed this warning may resuIt in
electrocution or other serious persona[ injury.