ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS
Open the front panel.
Pull up the front panel by holding it at both
sides with both hands.
2
Remove the filter.
Push upward to release the claws and pull out
the filter.
3
Attaching the air cleansing and deodorizing
filters to the filter.
Attach the air cleansing and deodorizing filters
to the frame by gently compress its both sides
and release after insertion into filter frame.
4
Attach the filters.
Attach the filters by ensuring that the surface
written FRONT is facing front.
After attaching the filters, push the front panel
at three arrow portion as shown in figure and
close it.
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.
CAUTION
!
!
CAUTION
Do not bend the air cleansing
and deodorizing filter as it may
cause damage to the structure.
NOTE
In case of removing the air cleansing and deodorizing filters, please follow the above procedures.
The cooling capacity is slightly weakened and the cooling speed becomes slower when the air cleansing
and deodorizing filters are used. So, set the fan speed to "HIGH" when using it in this condition.
Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum
cleaner or water rinse under running tap water. Type number for this air cleansing filter is
<SPX-CFH11>. Please use this number for ordering when you want to renew it.
Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.