16
Model with SOFT-TOUCH control panel
PHBS 6.8F LTI X - PHBS 9.8F LTI X
PHC6.7FLTIX - PHC9.7FLTIX
To select hood functions, simply touch the controls:
T1. Button ON/OFF suction motor
T2. Button to select medium suction speed (power)
T3. Button to select high and intensive suction speed (power)
Press once to select high suction speed (power) (LED L3 on);
Press again to select intensive suction speed (power) (LED L3 flashing).
Note: The intensive suction (power) speed lasts for approximately 5
minutes, then the high suction speed (power) is set automatically.
T4. Automatic shutdown button (Timer) and saturation indicator for
charcoal filter:
Automatic shutdown:
Press this button to set the automatic shutdown of the active suction speed
(power):
Silent suction speed (power): 10 minutes
Medium suction speed (power): 20 minutes
High suction speed (power): 15 minutes
Saturation indicator charcoal filter
When flashing, perform maintenance of the charcoal filter, if installed, then
keep the button T6 pressed for a long time to stop the flashing.
T5. Button to select ‘silent’ suction speed (power) and saturation indicator
for grease filter
Note: when flashing, perform maintenance of the grease filter; then keep
the button T6 pressed for a long time to stop the flashing.
T6. Button ON/OFF lighting
T3+T4+T5 flashing: automatic operation under high temperature conditions (see
relevant paragraph)
Activation of the charcoal filter saturation indicator
This indicator is normally deactivated. To activate it, proceed as follows:
With the hood off, press and keep pressed simultaneously T4 and T5: T5
starts flashing first, then T4 as well, to indicate successful activation.
Deactivation of charcoal filter saturation LED: repeat the operation
described above; T5 and T4 start flashing, then only T5 to indicate
successful deactivation.
Automatic operation under high temperature conditions
The hood is equipped with a sensor which detects the temperature. When this
becomes too high, the sensor automatically turns on the medium suction speed
(power). The hood turns off as soon as the temperature detected by the sensor
is lowered significantly.