User Manual Kenmore 79094383700 Range

Documents for Kenmore 79094383700

The following documents are available:
User Manual Photos
79094383700 photo
iNSTALLATiON AND SERVICE MUST BE PERFORMED BYA QUALiFiED iNSTALLER.
iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
Clearances and Dimensions
1. Provide adequate clearances between the range and adjacent combustibJe surfaces.
2. Location--Check location where the range will be installed. Check for proper eiectricaJ supply, and the stability of the
floor.
3, Dimensions that are shown must be used, Given dimensions provide minimum clearance, Contact surface must be solid
and level.
RANGE
OVERALL
DIMENSIONS
25- 3/4"
......_ 3o'--.j___
/
_-_- ;6+ 1/8'
" " \ 29-7/8" .. _
uoorupen \4r"'/_ _-- - -"
Fig. 1 Depthis 28-13/3Z'with doorhandle.
RANGEELECTRICAL
CONNECTIONS
__!1i dimensionsfoi "_
ectricaloutlet locationI
re maximum. J
h_/_ _j Dashedcubedarea /
_-Centenine showswherethe |
! ofrange electrical outlet must
II I beinstalledforflushto|
II -_i 11h_ the wall installation.
2-5/8"for modelsequipped
withwarmerdrawers,
3-1/2"for modelsequipped
withstoragedrawers Fig. 2
Minimumto 1"
walloneither
sideofrange
above36"height.
SIDE
VIEW
t Minimumto 1_-13"-_
18" cabinetson Maximumdepth
eitherside for cabinets II
,_ ofrange, aboverangetop.
Fig. 3
_25"_
iiill i i_
O"clearancebelow cookingtop andatrear ofrange.
*30" MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACEAND THE BOTTOM OF AN UNPROTECTED WOOD OR METAL
CABI NET; OR 24" MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT LESS THAN 1/4" FLAME RETARDANT
MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEETSTEEL, 0.015" STAINLESS STEEL, 0.024"ALUMIN UM OR 0.020" COPPER.
0" CLEARANCE IS THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO
PREVENT PROPERTY DAMAGE, POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOPAND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE LOCATED
ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN BE REDUCED BY
INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" BEYOND THE BOTTOM OF THE CABINETS.
IMPORTANT SAFETY INSTRUCTIONS
@
e ALL RANGES
CAN TiP
INJURYTO PERSONS
COULD RESULT
e INSTALL ANTI=TIP
DEVICE PACKED WITH
RANGE
SEE INSTALLATION
INSTRUCTIONS
If the information in this manual is not followed
exactly, a fire or electrical shock may result causing property
damage, personal injury or death,
Important Notes to the Installer
Read all instructionscontained inthese installationinstructions
before installingrange.
Remove all packing material from the oven compartments
before connecting the gas & electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your owner's guide for future
reference.
As when using any appliance generating heat, there are
certain safety precautions you should follow. These are
listed in the Use & Care Manual read it carefully.
Be sure your range isinstalledand grounded properly by
a qualified installer or service technician.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
To eliminate the need to reach over the surface elements,
cabinet storage space above the elements should be
avoided.
Serial Plate Locations:
Serial pJate location: i_#_/_ _</ r
Serial plateislocatedonthe lowerrightfrontframe oftheappliance.
Alternate location maybeunder cooktop.
pin 316454905 (0703) EN 1 EspaSol- Paginas 5-8