Loading ...
Loading ...
Loading ...
18
Lowes.com/harborbreeze
CARE AND MAINTENANCE
At least twice each year, lower the canopy to check the downrod assembly, and then tighten all
screws on the fan. Clean the motor assembly with only a soft brush or lint-free cloth to avoid
scratchingthenish.Cleanthebladeswithalint-freecloth.
Bulb Replacement: Use 60-watt max. candelabra-base bulbs or CFL equivalent.
Important: Shut off the main power supply before you begin any maintenance task. Do not use water
or a damp cloth to clean the fan.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan does not
move.
1. The reverse switch is not
engaged.
2. The wall switch is turned off.
3. The power is off or the fuse
(breaker) is blown.
4. There is a faulty wire
connection.
1. Firmly push the reverse switch
completely up or down.
2. Make sure the wall switch is turned on.
3. Turn the power on or check the fuse
(breaker).
4. Turn the power off and check all
connections at the ceiling outlet box.
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The wall control is not
compatible with the fan.
4. The outlet box is not secure.
5. The mounting bracket is not
secure.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer
switch to control the fan speed.
4. Ensure the outlet box is secured to
the building structure.
5. Ensure the mounting bracket is
secured to the outlet box and that
the screws are tight.
Loading ...
Loading ...
Loading ...