User Manual Siemens LI97RA540 iQ500 Flachschirmhaube 90 cm Edelstahl

Documents for Siemens LI97RA540

The following documents are available:
User Manual Photos
LI97RA540 photo
Extractor hood
[en] Instructions for installation and use
Loading ...
Loading ...
Loading ...

Specifications

Siemens LI97RA540 Questions and Answers


#1 Is an activated carbon filter part of the basic equipment? Does it have the same function as the replacement filter Clean Air? Do you need both filters for the recirculation mode?

No, the activated carbon filter is not included in the scope of delivery. The units are factory-equipped for exhaust air operation. If you want to operate the device in recirculation mode, you need either the starter set or the Clean Air recirculation module

#2 How can you clean the upper filter because it is covered by the pull-out and the pull-out cannot be removed. The two versions of the rougher filters are easy to remove

To avoid misunderstandings, we recommend that you contact the product advisory service directly for a personal consultation.

#3 Displey shows bars. What that means?

This is the saturation indicator for the metal grease filter.


#4 How do I get the rear filter out?

Removing the metal grease filter:
1. Extend the pull-out completely, open the lock and fold down the front metal grease filter. When doing so, reach under the metal grease filter with the other hand.
2. Remove the metal grease filter from the holder.
3. Take hold of the rear metal grease filter at both locks and fold down at an angle to the rear.