OPERATION MANUAL - Page 5

For ASO920X. Also, The document are for others Artusi models: ASO601RX, ASO901RX, ASO620X

Loading ...
Loading ...
Loading ...
7
E
X
TRAC
T
OR H
O
O
D
Dear Customer,
Thank you for buying our hood. Please read these instructions carefully
for its optimum installation, use and maintenance.
Notes: The gures mentioned in this manual are in the rst pages.
This hood is designed for tting in a cabinet or on some other support.
Warning: consult local regulations regarding fumes outlets. Do not
connect the hood to a fume, ventilation or hot air duct. Conrm
that room ventilation is appropriate with the local authorities.
Make sure
the maximum air extraction ow rate for the appliances in the room
does not exceed 4 Pa (0.04 mbar).The room must have adequate
ventilation if an extractor hood is used simultaneously with appliances
that run on gas or other fuels. The evacuated air must be extracted
through ducts that are used for evacuating fumes from appliances that
run on gas or other fuels. Regulations regarding air extraction must be
complied with.
This product in intended for HOUSEHOLD USE only.
Use a rigid PVC pipe with a min. Ø l20 mm to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to
outside
(recirculation system with activated charcoal lter).
Install the hood in line with the instructions on the template
Install the hood in line with the instructions on the template
provided.
For gas cooking appliances only: the minimum distance to the hood
must be at least 65 cm.
INSTALLATION
The cooker hood is supplied with
1 Spacer (F)
4 Screws
2 Bulbs
Close the space that remains between the hood and the wall,
adjunsting the spacer (F).
Before completing any connection, make sure the house voltage
corresponds with the voltage indicate on the data label.
Connecting the hood to the grid
Warning: before connecting the hood: switch off the electricity
supply and check that the supplied voltage and frequency
coincide with that indicated on the appliance nameplate.
If the extractor hood has a plug, connect it to a power socket in line
with applicable regulations, located in an accessible area.
If the hood does not have a plug, connect it directly to the electrical
grid, protected by a separator device accessible for disconnection, in
line with local regulations.
The connection to the electrical mains must be made as follows:
BLUE………………………..”N” NEUTRAL
BROWN……………………..”L” LIVE
GREEN AND YELLOW……(simbolo tierra) EARTH
If the terminals of the plug are unmarked or if you are in any doubt
consult a qualied electrician.
If it is not supplied t a plug normalized in the cord for the load showed
on the rating plate.
USE OF THE HOOD – SAFETY
Warning: the hood may stop working during an electrostatic
discharge (e. g. lightning). This involves no risk of damage. Switch
off the electricity supply to the hood and reconnect after one
minute.
Do not allow the hood to be used by children or persons with reduced
(physical, sensory or mental) capabilities or lack of experience and
knowledge, unless they have been given instruction concerning use of
the appliance by a person responsible for their safety.
Children should be supervised so that they do not play with the
appliance.
To avoid the risk of re, clean the metal lter regularly, permanently
control pans containing hot oil and do not ambé food underneath
the hood.
Do not use the hood if it shows signs of damage or imperfection.
Contact an ofcial distributor or authorised dealer.
Accessible parts may heat up when using cooking appliances.
OPERATION INSTRUCTION
SWITCH ON THE LAMPS (C-1, FIG.2)
• Pull out the grill (G) more than 50 mm,
• Slide the switch (C-1) from position *0” to “1”.
• ASPIRATE SPEED (FIG.2)
• Pull out the grill (G) more than 50 mm
• Slide the switch (C-2) from position “0” to “1” allow speed.
• Adjust the aspirate speed at mid speed by Slide the switch (C-3) from
position “ 1” to “2”
• Adjust the aspirate speed at high speed by Slide the switch (C-3) form
position “2” to “3”
Switch off the appliance by slide the switch (C-2) from position “1”
to “0”
• LED (C-4) will be lighted up when the aspirate motor operate.
YOU CAN CHANGE THE SPEED DURING OPERATION.
SUCTION VERSION
If the hood is to be installed as a SUCTION hood, connect the plastic
outlet piece (A) supplied with the hood (125mm diameter pipe for
better performance and lower noise levels.
FILTERING VERSION (INTERNAL RE-CYCLING)
When there is no exhaust duct for venting out-door, you can use a
carbon lter (D). The air is depurate by the lter and put again in the
surrounding.
The air is released in the room through a connecting pipe, which goes
through the hanging cupboard and us connected to the connecting
ring supplied (A) Fig 1.
To use the appliance in this version, proceed as follows:
Open the grids (E)
To proceed to change the charcoal lter (D).
Reinstall the grids.
HOOD MAINTENANCE
Warning: always switch off the electricity supply before carrying
out maintenance work on the hood. In the event of a fault,
contact an ofcial distributor or authorised dealer.
Exterior cleaning: use non-corrosive, liquid detergent and avoid the use
of abrasive cleaning products.
Grease lters: to avoid res, clean thoroughly once a month or whenever
the display pilot light indicates as such. To do so, remove the lters and
wash with hot water and detergent. If using a dishwasher, position the
lters vertically to prevent solid remains from depositing on them.
Activated charcoal lters: replace the every 2 months.
Important: increase the lter cleaning/replacement frequency if
the hood is used for more than 2 hours a day. Always use genuine
lters from the manufacturer.
Bulb replacement (look for the symbol in the gures)
Warning: do not handle the bulbs until the electricity supply has
been switched off and they have cooled.
Important: use new bulbs according to that indicated on the hood
nameplate.
Use bulbs with an aluminium reector to replace halogen bulbs. Do not
use dichroic bulbs - risk of overheating.
On cooker hoods equipped with tungsten lamps, the lights should only be used
during operation of the motor. They should not be left on permanently and
used as a light source.
Legal information
The manufacturer:
- Declares that this product meets all basic requirements regarding low-
voltage electrical equipment established in Directive 2006/95/EC of
12 December 2006 and electro-magnetic compatibility established in
Directive 2004/108/EC of 15 December 2004.
- Is not responsible for any failure to observe the instructions given in
this manual and current safety regulations for the correct use of the
equipment.
- Reserves the right to make any modications to the equipment or this
manual without prior notice.
Contact our ofcial distributor should you require technical assistance
or additional information on our products.
EN
FILTERED VERSION (INTERNAL RECYCLING)
ASO601RX & ASO901RX ONLY
FILTERED VERSION (INTERNAL RECYCLING)
ASO601RX & ASO901RX ONLY
Loading ...
Loading ...
Loading ...