13
Install the Case in the Window
Open the window and mark the centerline of
the window stool.
Carefully place the case on the window stool
and align the center mark on the bottom front
with the centerline of the stool.
Pull the window down behind the top
mounting rail.
NOTE: Do not shut the window so tightly that movement
of the accordion panels is restricted.
Loosely assemble the sill supports.
Select the position that will place the sill
supports near the outermost point on the sill.
Attach the sill supports to the case track hole in
relation to the selected position using 2 type A
screws in each support.
Adjust the bolt and the nut in each support so
that the case is installed with a slight tilt to the
outside. Use a level; about 1/3 bubble will be
the correct case slant to the outside.
Secure the case to the window stool by using
3 type B screws.
Pull the accordion panels to each window
sash track. Attach them on each side to the
window sash and the window stool using
4 type C screws.
H
G
F
E
D
C
B
A
5
Bolt Nut
Frame guide
Sill support
OUTDOOR
Sill
support
INDOOR