User Manual Whirlpool MMV5220FE cooking

Documents for Whirlpool MMV5220FE

The following documents are available:
User Manual Other Documents
  • Dimension Guide - (English) Download
  • Quick Reference Guide - (English) Download
  • Installation Instructions - W10823835 Rev A - (English) Download
PRODUCT MODEL NUMBERS
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
MMV5220F
Page 1 of 2
Ref. W10823835A
09/21/2016
MMV5219FMMV4205F
MMV4206F
Microwave Hood Combination
INSTALLATION DIMENSIONS:
NOTE: The grounded 3 prong outlet must be inside the upper cabinet.
See “Electrical Requirements” section.
12" (30.5 cm) min.
14" (35.6 cm) max.
30"
(76.2 cm)
min.
A B
upper cabinet and
side cabinet depth
30"
(76.2 cm)
typical*
66" (167.6 cm) min.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
* 30" (76.2 cm) is typical for 66" (167.6 cm) installation height. Exact
dimensions may vary depending on type of range/cooktop below.
PRODUCT DIMENSIONS
29
⁷⁄₈
" (76.0 cm)
17
¹⁄₈
"
(43.5 cm)
+/-
³⁄₁₆
"
(0.5 cm)
16
¹⁄₄
"
(41.3 cm)
Up to
16
³⁄₄
"
(42.5 cm)*
* Overall depth of product will vary slightly depending on door design.
ELECTRICAL REQUIREMENTS
Observe all governing codes and ordinances.
Required:
A 120 volt, 60 Hz, AC only, 15- or 20-amp electrical supply with a fuse
or circuit breaker.
Recommended:
A time-delay fuse or time-delay circuit breaker.
A separate circuit serving only this microwave oven.
VENTING DESIGN SPECIFICATIONS
This section is intended for architectural designer and builder/contractor
reference only.
NOTES:
Vent materials needed for installation are not provided with microwave
hood combination.
We do not recommend using a flexible metal vent.
To avoid possible product damage, be sure to vent air outside, unless
using recirculation installation. Do not vent exhaust air into concealed
spaces, such as spaces within walls or ceilings, attics, crawl spaces
or garages.
For optimal venting installation, we recommend:
Using roof or wall caps that have back draft dampers.
Using a rigid metal vent.
Using the most direct route by minimizing the length of the vent and
number of elbows to provide efficient performance.
Using uniformly sized vents.
Using duct tape to seal all joints in the vent system.
Using caulking compound to seal exterior wall or roof opening around
cap.
Not installing 2 elbows together for optimal hood performance.
If venting through the wall, be sure that there is proper clearance within
the wall for the damper to open fully.
If venting through the roof, and rectangular to round transition is used,
be sure there is at least 3" (7.6 cm) of clearance between the top of the
microwave oven and the transition piece. See “Rectangular to Round
Transition” illustration.
Roof venting Roof cap
Wall venting Wall cap