4. Apply masking tape to the end of a 9/32" (7.0 mm) nut driver
to help hold the propane gas orifice spud in the nut driver
while changing it. Press nut driver down onto the propane
gas orifice spud and remove by turning it counterclockwise
and lifting out. Set the propane gas orifice spud aside.
Use the following chart for correct Natural gas orifice spud for
each burner. Refer to the model/serial rating plate behind the
control panel for proper sizing of Natural orifice spuds for each
burner location.
Natural Gas Orifice Spud Chart
Burner Rating Color Number
5. Replace the propane gas orifice spud with correct Natural
gas orifice spud. See the “Natural Gas Orifice Spud Chart.”
6. Replace burner base and hand tighten the screws.
7. Replace burner cap.
8. Repeat steps 1 through 7 for the remaining burners.
9. Place propane gas orifice spuds in plastic parts bag for
future use and keep with literature package.
10. Replace burner grates.
11. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
1/4" (6.35 mm) to 1/2" (1.3 cm) long. The outer cone is not
as distinct as the inner cone. Natural gas flames do not have
yellow tips.
IMPORTANT: You may have to adjust the low setting for
each cooktop burner.
Moving the Range
When moving range, slide range onto cardboard or hardboard to
avoid damaging the floor covering.
If removing the range is necessary for cleaning or maintenance:
For Power Supply Cord-Connected Ranges:
1. Slide range forward.
2. Turn manual shutoff valve to the closed position.
3. Unplug the power supply cord.
4. Disconnect the gas supply tubing.
5. Complete cleaning or maintenance.
6. Reconnect the gas supply tubing.
7. Open the manual shutoff valve in the gas supply line.
8. Plug in power supply cord.
9. Slide range back so rear range foot is under anti-tip bracket.
10. Refer to the “Verify Anti-Tip Bracket Is Installed and
Engaged” section to verify engagement.
11. Check that range is level.
A
A. Propane gas orifice spud
5,000 BTU
7,300 BTU
9,200 BTU
10,000 BTU
15,000 BTU
16,000 BTU
Green
Yellow
Orange
Transparent
White
Black
107N
125N
142N
149N
180N
195N
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.