Loading ...
Loading ...
Loading ...
Installation
59
EN
Burner and nozzle specifications tables
1 Natural gas G20 - 20 mbar AUX SR RR UR2 int + ext UR3
Rated heating capacity (kW)
1.10 1.70 2.60 1.10 + 3.90 3.90
Nozzle diameter (1/100 mm)
73 92 115 73 + 140 140
Reduced flow rate (W)
400 450 650 400 + 1200 1400
Primary air (mm)
1.5 1.5 1 2 + 3 2
2 Natural gas G20 - 25 mbar AUX SR RR UR2 int + ext UR3
Rated heating capacity (kW)
1.10 1.70 2.60 1.10 + 3.90 3.9
Nozzle diameter (1/100 mm)
73 87 110 73 + 132 132
Reduced flow rate (W)
400 450 650 400 + 1200 1400
Primary air (mm)
1.5 1 1 3 + 4 1.5
3 Natural gas G25.1 – 25 mbar AUX SR RR UR2 int + ext UR3
Rated heating capacity (kW)
1.10 1.70 2.60 1.10 + 3.90 3.90
Nozzle diameter (1/100 mm)
76 98 123 76 + 150 150
Reduced flow rate (W)
400 450 650 400 + 1200 1400
Primary air (mm)
1.5 1.5 1 1.5 + 3 1.5
4 Natural Gas G25 – 20 mbar AUX SR RR UR2 int + ext UR3
Rated heating capacity (kW)
1.10 1.70 2.60 1.10 + 3.90 3.90
Nozzle diameter (1/100 mm)
82 98 126 82 + 155 155
Reduced flow rate (W)
400 450 650 400 + 1200 140
Primary air (mm)
1.5 1.5 1 1.5 + 3 1.5
5 Natural gas G2.350 – 13 mbar AUX SR RR UR2 int + ext UR3
Rated heating capacity (kW)
1.10 1.70 2.60 1.10 + 3.90 3.90
Nozzle diameter (1/100 mm)
100 126 160 100 + 200 200
Reduced flow rate (W)
400 450 650 400 + 1200 1400
Primary air (mm)
1.5 1.5 1 2 + 2 3
Loading ...
Loading ...
Loading ...