Loading ...
Loading ...
Loading ...
Place level against top front opening of tub. Check that
dishwasher is level from side-to-side. If dishwasher is not level,
adjust front legs up or down until dishwasher is level. Close the
dishwasher door.
;iFii
Copper tubing only: Slide nut, then ferrule, about 1" (2.5 cm)
onto copper tubing.
NOTE: To avoid vibration during operation, route the water
supply line so that it does not touch the dishwasher base, frame
or motor.
Connect the 3/8" compression fitting to the water supply line
prior to installing the unit into the cabinet opening. Attach such
that the 3/4" connection is facing upward as shown above.
Copper tubing only: Put the tubing into the 90 ° elbow fitting as
far as it will go (the copper tubing bends and kinks easily). Slide
the nut and ferrule forward and start the nut onto the elbow
threads.
Flexible braided connection: Secure nut to elbow using 5/8" open
ended wrench or adjustable wrench.
NOTE: Do not use Teflon ®t tape with compression fittings.
Be sure rubber washer is properly seated in fitting. Slide the
3/4" fitting up to the valve and hand tighten to avoid cross-
threading. Hand tighten until the coupling is tight.
Using pliers, check the tightness of the coupling. An additional
1/4to 1/2 turn may be required to seal the rubber gasket.
NOTE: Do not overtighten. Damage to the coupling can result.
Place paper towel under 90 ° elbow fitting. Turn on water supply
and check for leaks. If leak occurs, repeat previous step.
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.