Empava Gas Rangetops
9
Installaon with a range hood
Note: Minimum clearance for back wall is 0” with backsplash (backguard) or high shelf.
If a range hood is installed above the range top, maintain a 30” (76.2 cm) minimum clearance between
the rangetop and the boom o he range hood.
The range hood must exhaust outside.
For best smoke eliminaon, the minimum clearance o he range hood should be installed 30” to 36”
above the rangetop surface. Recommended CFM should be 600 CFM for the 30” range top.
Do no nstall with a downdra venlaon system
Installaon in an island
Note: There must be a minimum of 6” (15.2 cm) clearance from rear of range top to a combusble wall.
Clearances from non-combusble materials are not part o he ANSI Z21.1 scope and are not cerfied
by CSA. Clearances to non-combusble materials must be approved by the authority having jurisdicon.
This range top may be installed directly adjacen o exisng 36” (91.4 cm) high base cabinets.
The range top CANNOT be installed directly adjacen o sidewalls, tall cabinets, tall appliances, or
other side vercal surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm)
side clearance from the range top to such combusble surfaces above the 36” (91.4 cm) counter
height.
Within the 6” (15.2 cm) side clearance to combusble vercal surfaces above 36” (91.4 cm), the
maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side
clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.
Wall cabinets above the range top must be a minimum of 42” (106.7 cm) above the range top
cooking surface for the full width o he range top. This minimum height requirement does not
apply if a range top hood is installed over the cooking surface.