SEMI-PERMANENT WALL INSTALLATION
In some cases a window opening might not be assessable; therefore this appliance is supplied with semi-permanent 
wall ange kit that can be connected the Exhaust Duct.
WARNING
The positioning and installation of the wall ange should be completed by an authorised person
and must comply with all municipal building codes and OH&S guidelines.
CONDENSATE DRAINAGE
NOTE
Condensate produced by this appliance is NOT potable,
dispose of via waste outlet or allow to evaporate.
INTERNAL CONDENSATE TANK
During  operation  the  appliance  may  produce  small  amounts  of 
condensate. The appliance has an inbuilt condensate tank. If all three 
drain  outlets  (7),  (8)  and  (12)  are  plugged,  then  this  tank  may  reach 
capacity.  If  this  happens,  the  appliance  will  stop  operation  and  the 
condensate  full  code  “P1”  will  be  shown  on  the  control  panel  display 
and the condensate tank will need to be drained before operation can 
be resumed. To do this:
1. Place shallow tray such as an oven baking tray or similar (with at 
least a 1 litre volume) under Drain Tray Outlet (12).
2. Remove the plug from Drain Tray Outlet (12) and drain out the
condensate  water,  once  the  condensate  is  drained  replace  the 
plug, the appliance will now be able to then resume operation.
FIXED CONDENSATE DRAINAGE HOSE
As an alternative to using the appliances internal condensate tank, a condensate drain hose (20) may de tted.
Option 1 - External Drain Tray: with drain outlets (8) and (12) plugged, t the condensate drain hose (20) to drain 
outlet (7) and drain the condensate into a drain tray.
Option 2 - Existing Waste Outlet: with drain outlets (7) and (8) plugged, t the condensate drain hose (20) to drain 
outlet (12) and drain the condensate into a drain tray or waste outlet.
NOTE
The point to which the condensate is to be drained MUST BE lower than the drainage outlet point.
When using a drain tray option, ensure that the capacity of the tray is greater than that of the
condensate being produced.
7
8
12
Shallow baking tray
Option
2
Option
1
7
8
12
7
8
12