SEMI-PERMANENT WALL INSTALLATION
In some cases a window opening might not be assessable; therefore this appliance is supplied with semi-permanent
wall ange kit that can be connected the Exhaust Duct.
WARNING
The positioning and installation of the wall ange should be completed by an authorised person
and must comply with all municipal building codes and OH&S guidelines.
CONDENSATE DRAINAGE
NOTE
Condensate produced by this appliance is NOT potable,
dispose of via waste outlet or allow to evaporate.
INTERNAL CONDENSATE TANK
During operation the appliance may produce small amounts of
condensate. The appliance has an inbuilt condensate tank. If all three
drain outlets (7), (8) and (12) are plugged, then this tank may reach
capacity. If this happens, the appliance will stop operation and the
condensate full code “P1” will be shown on the control panel display
and the condensate tank will need to be drained before operation can
be resumed. To do this:
1. Place shallow tray such as an oven baking tray or similar (with at
least a 1 litre volume) under Drain Tray Outlet (12).
2. Remove the plug from Drain Tray Outlet (12) and drain out the
condensate water, once the condensate is drained replace the
plug, the appliance will now be able to then resume operation.
FIXED CONDENSATE DRAINAGE HOSE
As an alternative to using the appliances internal condensate tank, a condensate drain hose (20) may de tted.
Option 1 - External Drain Tray: with drain outlets (8) and (12) plugged, t the condensate drain hose (20) to drain
outlet (7) and drain the condensate into a drain tray.
Option 2 - Existing Waste Outlet: with drain outlets (7) and (8) plugged, t the condensate drain hose (20) to drain
outlet (12) and drain the condensate into a drain tray or waste outlet.
NOTE
The point to which the condensate is to be drained MUST BE lower than the drainage outlet point.
When using a drain tray option, ensure that the capacity of the tray is greater than that of the
condensate being produced.
7
8
12
Shallow baking tray
Option
2
Option
1
7
8
12
7
8
12
INSTALLATION