PARTS AND FEATURES

KEY PARTS AND COMPONENTS

1. Air discharge

The adjustable louvered air discharge opens automatically when the air conditioner is turned on, and closes when it is turned off. It can also be set to oscillate to distribute air more evenly through the room.

2. CONTROL PANEL AND DISPLAY

Easy-to-read digital display shows the set temperature, and indicator lights show the operating mode. Simple push buttons make changing settings quick and easy.

3. SWIVELING CASTERS

Swiveling casters allow you to move the air conditioner easily on most floor surfaces.

4. INTEGRATED HANDLES

Integrated handles provide a convenient grip when lifting the air conditioner.

5. INFRARED REMOTE CONTROLLER

The remote controller allows you to adjust the temperature and operate most functions of the air conditioner from across the room.

6. BOTTOM DRAIN PORT

Before moving the air conditioner, drain the internal water is in the collection tank using the bottom drain port.

7. AIR FILTER

8. HOSE AND DIFFUSER

Use the diffuser and hose to connect the air conditioner to the window installation kit to vent exhaust air outside.

HOW TO USE

BEFORE USING THE AIR CONDITIONER

PREPARING FOR OPERATION

Refer to the Installation Instructions included in this manual before using the air conditioner. Once the air conditioner has been properly assembled and installed:

  1. Plug the power cord into its own dedicated properly grounded outlet. Do not plug other appliances into the same outlet.
  2. Doing so could overload the outlet and create a fire hazard. are they do tripping hazard and will receive adequate place the appliance near furniture or objects that could block the vent openings.
  3. Make sure that any items that could be blown over or damaged by the airflow from the fan are out of the airflow path.

IMPORTANT:

• Do not remain in the direct airflow from the air conditioner for extended periods of time.

• When used at the same time as stoves, fireplaces, and other combustion devices, make sure there is a sufficient flow of fresh air into the room. Do not use in tightly enclosed spaces with these types of devices.

• This air conditioner is intended for household use as a consumer comfort appliance. Do not use it as a precision climate control system, or for purposes such as cooling precision equipment, food, pets, plants, artwork, etc. Such items could be damaged.

• Do not bend the hose downward when window installation kit is not applied. It may cause failure of air conditioner or performance deterioration.

UNPACKING THE AIR CONDITIONER

Remove and store packing materials for reuse. Remove any shipping tape before using the air conditioner. If the tape leaves behind any adhesive, rub a small amount of liquid dish soap onto it and wipe with a damp cloth. Do NOT use sharp instruments, alcohol, thinners, or abrasive cleaners to remove adhesive. They could damage the finish.

BEFORE USING THE AIR CONDITIONER

INSERTING BATTERIES IN THE REMOTE

Before using the remote, install the provided AAA batteries.

  1. Press and slide to remove the battery cover on the back of the remote.
  2. Insert two new alkaline AAA batteries into the battery compartment, being sure to note the proper polarity.
  3. Reattach the battery cover.

NOTE :

• Use only alkaline batteries. Do not use rechargeable batteries.

• When replacing batteries, always replace both batteries with new batteries. Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, etc) batteries.

• If the air conditioner will not be used for an extended period of time, remove the batteries from the remote.

REMOTE STORAGE

The air conditioner is designed with a convenient storage compartment for the remote.

NOTE:

When not in use, store the remote in the storage compartment with the buttons facing out.

WARNING

• If the batteries leak onto your clothes or skin, remove contaminated clothing and rinse skin thoroughly with soap and water. Do not use the remote if the battery has leaked.

• If the battery or the liquid inside it are ingested, do not induce vomiting or give food or drink. Contact a physician immediately.

CONTROL PANEL AND REMOTE

Operation of functions is the same when using the remote or the control panel, unless otherwise stated. The remote and the control panel are not in sync.

For best results when using the remote, remember to check that all desired settings are correct on the remote as well as on the control panel.

NOTE:

  • The remote sensor is located on the front panel of the air conditioner. Point the remote from anywhere at the sensor.
  • The remote may not work if the sensor is in bright light or if there is not a clear path between the remote and the sensor.
  • Some functions may not be supported, depending on the model.

1. POWER

Turns the air conditioner on and off.

A chime sounds to confirm you have turned it on or off.

2. MODE

Press this button repeatedly to toggle through and select the operating mode. Modes include Cool, Dry (dehumidify), and Fan. An LED illuminates to indicate the selected mode. The default mode is Cool. See the Operation section for more information.

3. FAN

Press repeatedly to toggle the fan speed between High and Low settings. An LED illuminates to indicate the selected fan speed. The fan speed can be changed in the Cool, and Fan modes. The fan speed is preset in the Dry mode. After pressing the button, there is a brief delay before the fan motor changes speed.

4. TIMER

Use the timer function to set the air conditioner to turn on or off at a desired time. See the Operation section for more information.

5. (TEMP/TIMER)

In COOL mode, the ∧/∨ buttons adjust the set temperature up to 86°F or down to 60°F, in one-degree increments. When the TIMER function is selected, use the ∧/∨ buttons to adjust the delay time from 0 to 24 hours, in one-hour increments.

NOTE : In COOL mode, the thermostat in the air

conditioner runs the compressor until the set temperature is reached, then cycles the compressor on and off to maintain the set temperature.

6. SWING

Sets the air discharge louvers to open and shut, circulating the air more effectively through the room.

If the louvers do not move properly, unplug and plug in the power cord.

NOTE : Press and hold the Fan button on the control panel for 3 seconds to set Swing.

7. LIGHT

Turn on/off the Display screen.

NOTE : Press and hold the Timer button on the control panel for 3 seconds to set Light.

8. °C/°F

Remotely change units between °C and °F

NOTE : To change units from the control panel, press and hold the A and V buttons at the same time.

9. LED DISPLAY

LED display shows the set temperature, fan speed, or the selected TIMER delay.

LEDs illuminate to indicate the active Mode, fan speed, and other settings. An FL error code displays when the water drain tank needs to be emptied.

OPERATION

MODES

COOL

Compressor runs and cools the room. Use the ∧/∨ and FAN buttons to set the desired temperature and fan speed. The desired temperature can be set from 60°F to 86°F (16°C to 30°C) in one-degree increments.

FAN

Fan circulates air but compressor does not run. Use the FAN button to set the desired fan speed to either High or Low.

DRY

Use the Dry mode to remove humidity from the room without additional cooling. This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity.

RESTARTING THE AIR CONDITIONER AUTOMATICALLY

When the air conditioner is turned on again after a power failure, this function restores the previous Settings.

TIMER

Use the Timer function to turn the air conditioner ON/OFF automatically

Setting the Air Conditioner to Turn ON

  1. Plug in the air conditioner and power it ON.
  2. Set the desired mode, temperature, fan speed, etc.
  3. Power OFF the air conditioner.
  4. Press Timer and use the buttons to set the desired delay time until the air conditioner turns ON. The delay time can be set from 0 to 24 hours in one-hour increments.
  5. The Timer LED on the air conditioner illuminates, and the delay time appears on the remote and in the control panel.
  6. To cancel the Timer function, press Timer twice.

Setting the Air Conditioner to Turn OFF

  1. Plug in the air conditioner and power it ON.
  2. Set the desired mode, temperature, fan speed, etc.
  3. Press Timer and use the buttons to set the desired delay time until the air conditioner turns OFF. The delay time can be set from 0 to 24 hours in one-hour increments.
  4. The Timer LED on the air conditioner illuminates, and the delay time appears on the remote. The delay time appears briefly in the control panel and is then replaced by the set temperature.
  5. To cancel the Timer function, press Timer twice.

NOTE: To check the remaining time, press Timer.

CARE AND CLEANING

Your air conditioner is designed for year-round operation with only minimal cleaning and maintenance.

For maximum efficiency, it is recommended that you have the cooling coils inspected and cleaned annually. Your local LG Authorized Service Center can provide this inspection and cleaning service for a nominal fee.

WARNING

• Unplug the air conditioner before cleaning or performing any maintenance or servicing.

• Be careful when cleaning coils or removing or reinstalling the filter—the cooling fins are sharp!

Failure to follow the above precautions could result in electric shock or personal injury.

EMPTYING THE WATER COLLECTION TANK

This product has a self-evaporative system. The condensing water will be recycled to cool the condenser. This not only improves cooling efficiency but also saves energy for you.

Using the Upper Drain Port (Dry Mode Only)

• This can be used when you need dehumidification in high humidity.

• The upper drain port is not used in the Cool or Fan mode.

• Remove the drain plug when using the Dry (dehumidifying) mode.

• Install a drain hose (12mm [1/2"] outer diameter) and place the open end of the hose over a drain or bucket or out the window.

Using the Lower Drain Port

* Unplug the air conditioner, disconnect the exhaust hose from the back, and move the air conditioner to a suitable drain location or outdoors. You may also place a pan under the drain that will hold up to 2 pints of water.

* Remove the drain cap from the drain outlet.

* Once the water collection tank is drained, reinstall the drain cap, making sure it is on securely.

* Place the air conditioner in the desired location, reconnect the exhaust hose, and plug in the air conditioner.

CLEANING THE CASE

Wipe the case with a slightly damp cloth, then wipe dry with a dry cloth or towel.

• To prevent damage to the finish, do not use gasoline, benzene, thinner, etc., or any abrasive cleansers to clean the air conditioner; they may damage the finish.

• Never pour water onto or into the air conditioner. It could damage internal components and create a shock and fire hazard.

CLEANING THE AIR FILTER

The air filters should be cleaned every two weeks; depending on indoor air quality, more frequent cleaning may be needed. A dirty air filter will decrease airflow and reduce efficiency.

Do not operate the air conditioner without the air filters in place.

  1. Pull out each air filter by the handle.
  2. Use a vacuum cleaner to clean the filters. If the filters are heavily soiled, they can be washed in warm water using a mild detergent.
    • Do not use harsh cleaners or very hot water.
    • Do not wash in a dishwasher.
  3. Allow the filters to dry completely before reinstalling.
  4. Reinsert the filters.

STORING THE AIR CONDITIONER

If the air conditioner will not be used for an extended period of time:

  1. To drain the water collection tank completely, leave the bottom drain cap off long enough to allow any residual water to drain out. Once the tank is completely drained and no more water flows out, reinstall the cap.
  2. Remove and clean the filters, allow them to dry completely, then reinstall them.
  3. Remove the batteries from the remote.
  4. Store the air conditioner in a cool, dry location, away from direct sunlight, extreme temperatures, and excessive dust.

Before using the air conditioner again:

  1. Make sure the filters and drain cap are in place.
  2. Check the power cord to make sure it is in good condition, with no cracks or damage.
  3. Place new batteries in the remote.
  4. Install the air conditioner as described in the Installation Instructions.

TROUBLESHOOTING

BEFORE CALLING FOR SERVICE

Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of a defect in workmanship or materials.

ProblemPossible causesCorrective Action
Air Conditioner does not start.The air conditioner is unplugged.Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power failure.

If power failure occurs, unplug the unit.

When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

The current interrupter

device is tripped.

Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
FL appears in the displayThe water collection tank is full. Drain the tank and reset your settings.
Room temperature is less than the set temperature.

This is normal. The air conditioner automatically shuts off when the room temperature equals or is less than the set temperature.

Set the desired temperature to a level lower than the current temperature.

Air Conditioner does not cool as it should.Airflow is restricted.Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The temp control may not be set correctly.Set the desired temperature to a level lower than the current temperature.
The air filters are dirty.

Clean the filters at least every 2 weeks.

See the Care and Cleaning section.

The room may have been hot.

When the air conditioner is first turned on, you need to allow time for the room to cool down.

Air Conditioner freezing up.The cooling coils are iced over.

Ice may block the air flow and obstruct the air conditioner from properly cooling the room.

Set the mode control at High Fan or High Cool.

Air Conditioner runs too oftern or too long.Area to be cooled is too large for the air conditioner.Consult your dealer for the air conditioner capacity necessary to cool the desired area.
Doors or windows are open.Make sure doors and windows are closed.

Noise when unit is cooling.

Air movement sound.This is normal. If too loud, set to lower Fan setting.

Remote

sensing

deactivating

prematurely.

Remote control not located within range.Place remote control within 20 feet and 120° radius of the front of unit.
Remote control signal obstructed.Remove obstruction.

Error Code

Possible causes

Corrective Action

Code appears in the display. FL

Water tank is full.

Drain water from the product through drain hole and reset settings.

CH 01 CH 02

Short/open circuit in thermistor.

Unplug the air conditioner and contact an authorized LG service center.



See other models: 65UH6550 RC897T BPM35 BP340 DLEX7700VE

LG Electronics LP1218GXR | File type: PDF | Filename: lp1218gxr.pdf | Size: 5.54 MB | Language: English | Other documents: 2 files.

Download User Manual

Product Infomation and Reviews - LP1218GXR photo

LP1218GXR Photo

LG Electronics in United States

(800) 243-0000 Consumer (7am-midnight CST) (888) 865-3026 Commercial (8am-6pm CST)