TECHNICAL SPECIFICATIONS – GAS DRYER
220–240 V~50 Hz 1ph 3 A max. IP24 Clothes capacity: 9.0 kg max. Sound pressure level, Lpa: 58 dBA (uncertainty, Kpa: +/-10 dBA) Total mass: 68 kg max.
Country: CH, CZ, CY, ES, GB, GR,
IE, IT, LT, PT, SI, SK, TR
BG, CY, CZ, DK, EE, FI, GR, HR,
IT, LT, NO, RO, SE, SI, SK
European Gas Category:
II
2H3+
II
2H3B/P
Gas Flow Rate: 0.562703 m
3
/hr 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar 20 mbar
Factory Adjusted Pressure: 7.4 mbar 7.4 mbar
European Country: CH, CZ, CY, ES, GB, GR,
IE, IT, LT, PT, SI, SK, TR
BG, CY, CZ, DK, EE, FI, GR, HR,
IT, LT, NO, RO, SE, SI, SK
European Gas Category:
II
2H3+
II
2H3B/P
Butane Supply Pressure (G30): 28–30 mbar 30 mbar
Adjusted Pressure: N/A N/A
Propane Supply Pressure (G31): 37 mbar 30 mbar
Adjusted Pressure: N/A N/A
European Country: FR, BE
European Gas Category:
I
2E+
Supply Pressure (G20): 20 mbar
Supply Pressure (G25): 25 mbar
Adjusted Pressure: N/A
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
With LP Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
With France/Belgium NATURAL GAS conversion kit: Injector size 1.65 mm Heat input gross: 5.9 kW
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country:
AT, BG, CH, CZ, DK, EE, ES, FI, GB, GR, HR,
IE, IS, IT, LT, LV, NO, PT, RO, SE, SI, SK, TR
European Gas Category: I
2H
Gas Flow Rate: 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar
Factory Adjusted Pressure (G20): 7.4 mbar
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
Country: LU, RO
European Gas Category: II
2E3B/P
Gas Flow Rate: 0.562703 m
3
/hr
Supply Pressure (G20): 20 mbar
Factory Adjusted Pressure (G20): 7.4 mbar
With L.P. Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
Country: LU, RO
European Gas Category: II
2E3B/P
Butane Supply Pressure (G30): 30 mbar
Adjusted Pressure: N/A
L.P. Supply Pressure (G31): 30 mbar
Adjusted Pressure: N/A