45
12. Technical Data
THE COOKER IS CATEGORY: CatII
2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia.
Pressures
Gas (Rp ½ at rear right-hand side) Electric
Supply Pressure
at the inlet to appliance regulator
230/400 V 50 Hz
Natural Gas 1.13 kPa
Propane 2.75 kPa
Operating Pressure
at appliance test point
Natural Gas 1 kPa
Propane 2.54 kPa
See the appliance badge for test pressures.
Dimensions
Model NEXUS 110 Dual Fuel
Overall height minimum 905 mm maximum 930 mm
Overall width 1092 mm
Overall depth 608 mm excluding handles, 648 mm including handles
Minimum height above the hotplate 650 mm
Hotplate Ratings
BSI Evo 1 Type Burners Australia
Burner Type
Input Rate MJ/Hr
Natural Gas Propane X Bypass Screw
Wok 15.2 15.0 55 **
Rapide 12.3 12.0 41 **
Semi Rapide 6.2 6.2 33 **
Auxillary 3.7 3.3 25 **
** The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural Gas. For LPG conversion the bypass
screws must be screwed all the way down.
Hotplate energy saving tips Oven energy saving tips
Use cookware with a at base. Cook meals together, if possible.
Use the correct size cookware. Keep the pre-heating time short.
Use cookware with a lid. Do not lengthen cooking time.
Minimise the amount of liquid or fat. Do not open the oven door during the cooking period.
When liquid starts boiling, reduce the setting. Do not forget to turn the appliance o at the end of cooking.
Consumption is based on G30.