To detach these parts from each
other, press the release button and
pull the telescopic wand out of the
suction nozzle, twisting it slightly as
you do so.
Adjusting the floorhead (Fig. 07)
(only for models with a reversible floor-
head included in the standard version)
This vacuum cleaner can be used for
the everyday cleaning of carpets, rugs
and hard flooring.
Miele offers a range of other floorheads,
brushes and accessories for other types
of flooring and special applications (see
"Optional accessories").
Please always follow the flooring
manufacturer's cleaning and care in-
structions.
Vacuum carpets and rugs with the
brush retracted:
Press the foot switch .
Clean hard flooring which is not sus-
ceptible to scratching, and flooring with
gaps or deep crevices in it with the
brush protruding:
Press the foot switch .
If the suction power of the floorhead
seems too high, reduce the suction
until the head is easier to maneuver
(see "Use - Regulating the suction
power").
Activating the TimeStrip® exhaust fil-
ter change indicator on the exhaust
filter
Depending on the model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters (Fig.
08).
a AirClean
b Active AirClean 50 (black)
c HEPA AirClean 50 (white)
If your vacuum cleaner is fitted with ex-
haust filter b or c, you need to activate
the TimeStrip® exhaust filter change in-
dicator.
Press the release button on the re-
cessed grip and raise the dust com-
partment lid as far as it will go (Fig.
09).
Remove the indicator strip (Fig. 10).
Press the TimeStrip® exhaust filter
change indicator(Fig. 11).
After approx. 10–15 seconds a thin red
line will appear in the left-hand side of
the display (Fig. 12).
Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the Fil-
terBag when doing so.
How the TimeStrip® exhaust filter
change indicator works
The TimeStrip® exhaust filter change
indicator shows the remaining func-
tional life of the exhaust filter. After ap-
prox. 50 operating hours, or approx.
one year of average use, the display will
be completely filled with red (Fig. 13).