System tested and certied by NSF International against NSF/ANSI
Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specied on the Performance Data Sheet.
Water Filtration System
Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentraion less than or
equal to the permissible limit for water leaving the system, as specied in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction
Aesthetic Effects
Inuent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.6%
Particulate Class I* At least 10,000 particles/mL 85% reduction 98.8%
Contaminant Reduction Inuent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 99.3% / 99.3%
Mercury: @ pH 6.5 / @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 95.1% / 95.0%
Asbestos 107 to 108 bers/L†† >99% >99%
Cysts† 50,000/L min. >99.95% 99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 98.1%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 94.4%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.6%
Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 86.8%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 98.8%
P-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.7%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.0%
Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.8%
Atenolol 200 ± 20% 30 ng/L >95.9%
Endrin 0.006 mg/L± 10% 0.002 mg/L 96.7%
Ethylbenzene 2.1 mg/L ± 10% 0.7 mg/L 99.9%
o-Dichlorobenzene 1.8 mg/L± 10% 0.6 mg/L 99.9%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 97%
Carbamazepine 1400 ± 20% 200 ng/L >98.6%
DEET 1400 ± 20% 200 ng/L >98.5%
Linuron 140 ± 20% 20 ng/L >96.8%
Meprobamate 400 ± 20% 60 ng/L 94.6%
Metolachor 1400 ± 20% 200 ng/L 98.3%
Trimethoprim 140 ± 20% 20 ng/L >96.4%
Bisphenol A 2000 ± 20% 300 ng/L 99.4%
Estrone 140 ± 20% 20 ng/L >96.7%
Nonylphenol 1400 ± 20% 200 ng/L >98.9%
Ibuprofen 400 ± 20% 60 ng/L 92.9%
Naproxen 140 ± 20% 20 ng/L >96.3%
Phenytoin 200 ± 20% 30 ng/L >94.8%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).