Safety Instructions Installation Instructions Operating Instruction Troubleshooting Tips Customer Service
Electrical
Connection
Options
If
your
home
has:
And
you
will
be
connecting
to
Go
to
Section
4-wire
connection:
Power
supply
cord
4-wire
direct
A
fused
disconnect
or
circuit
breaker
box*
4-wire
connection:
Direct
Wire
4-wire
receptacle
(NEMAType14-30R)
A
UL
listed,
120/240
volt
minimum,
30
amp,
dryer
power
supply
cord*
4-wire
connection:
Power
supply
cord
3-wire
receptacle
(NEMAtype10-30R)
A
UL
listed,
120/240
volt
minimum,
30
amp,
dryer
power
supply
cord*
3-wire
connection:
Power
supply
cord
3-wire
direct
A
fused
disconnect
or
circuit
breaker
box*
3-wire
connection:
Direct
Wire
lf
local
codes
do
not
permit
the
connection
of
a
frame-grounding
conductor
to
the
neutral
wire,
go
to
"Optional
3-wire
connection"
section.
1.
Remove
center
terminal
block
screw.
2.
Remove
appliance
ground
wire
(green)
from
external
ground
connector
screw.
Fasten
it
under
center,
silver
colored
terminal
block
screw.
1.
External
ground
connector
-
Dotted
line
shows
position
of
NEUTRAL
ground
wire
before
being
moved
to
center
terminal
block
screw
2.
Center
silver-colored
terminal
block
screw
3.
Green
wire
of
harness
1.
External
ground
connector
2.
Green
or
bare
copper
wire
of
power
supply
cord
3.
3/4
in.
(1.9
cm)
UL-listed
strain
relief
4.
Center
silver-colored
terminal
block
screw
5.
Neutral
grounding
wire
(green)
6.
Neutral
wire
(white)
5.
Connect
the
other
wires
to
outer
terminal
block
screws.
Tighten
screws.
6.
Tighten
strain
relief
screws.
7.
Insert
tab
of
terminal
block
cover
into slot
of
dryer
rear
panel
Secure
cover
with
hold-down
screw.
IMPORTANT:
A
4-wire
connection
is
required
for
mobile
homes
and
where
local
codes
do
not
permit
the
use
of
3
wire
connections.
Direct
wire
cable
must
have
5
ft
(1.52
m)
of
extra
length
so
dryer
can
be
moved
if
needed.
Strip
5
in.
(12.7
cm)
of
outer
covering
from
end
of
cable,
leaving
bare
ground
wire
at
5
in.
(12.7
cm).
Cut
V/2
in.
(3.8
cm)
from
3
remaining
wires.
Strip
insulation
back
1
in.
(2.5
cm).
Shape
ends
of
wires
into
a
hook
shape.
3.
Connect
ground
wire
(green
or
bare)
of
power
supply
cable
to
external
ground
conductor
screw.
Tighten
screw.
4.
Connect
neutral
wire
(white
or
center
wire)
of
power
supply
cord
to
the
center,
silver
colored
terminal
screw
of
the
terminal
block.
1.
4-wire
receptacle
(NEMA
type
14-30R)
2.
4-prong
plug
3.
Ground
prong
4.
Neutral
prong
5.
Spade
terminals
with
upturned
ends
6.
3/4
in.
(1.9
cm)
UL
approved
strain
relief
7.
Ring
terminals
IMPORTANT:
A
4-wire
connection
is
required
for
mobile
homes
and
where
local
codes
do
not
permit
the
use
of
3
wire
connections.
4-wire
connection:
Direct
wire
5"
(12.7cm)
1"
(2.5cm)
1
2
34
5
7
6
6
5
3
2
1
4
3
1
2