802006 - HT-BCS;BCSH A-AV User Manual - 09.2016- v3.01 Page 11 of 32
Light intensity varies from site to site, therefore it is recommended that a
re-calibration be performed at the time of the installation.
All direct natural sun light must be shaded from the HydroTap, during the
calibration. This can be achieved by closing any nearby curtains, blinds, etc.
or by shading the tap with a dark cloth.
Safety Sensor Calibration (lever models)
Pull both levers forward
Safety
sensor
1.
With the unit in Normal operating mode
and with the safety enabled
2.
Turn the power OFF
3.
Pull both tap levers to the forward
position
4.
Turn ON the power
5.
The unit will calibrate the safety switch
6.
Return the levers to the neutral
position.
7.
To check the calibration, dispense Boiling water, in normal light
conditions with the safety enabled.