INSTRUCTION MANUAL - Page 15

For SCR1400WLH. Also, The document are for others Summit models: SCR1536B, SCR1536BG, SCR2464, SCR1005W, SCR1155W, SCR1400W

Loading ...
Loading ...
Loading ...
15
The gasket is dirty.
The shelves are out of position.
Clean the door gasket.
Check the shelves and refit correctly.
Display “E0”,
“E1”. “E2”,
“E3”, “E4”,
“E5”, “E6” or
“E7”.
“E0” indicates a communication error for
3 zone models.
“E1” or “E2” indicates that the air
temperature sensor has failed.
“E3” or “E4” indicates that the defrost
sensor in the evaporator has failed.
“E5” indicates a defrost heater failure.
“E6” indicates a solenoid valve failure.
“E7” indicates a door switch failure.
Call for service.
The alarm
sounds and
the
temperature
display
flashes.
Has the appliance door been open for
longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the set temperature. This
could be due to:
The appliance door has been opened
too often.
The ventilation opening is covered or
too dusty.
A lengthy interruption to the power
supply.
A large number of items has been
added to the unit.
If yes, close the door.
Do not open the door more often than
necessary.
Clear the obstructions and clean off
the dust.
Let the appliance work for a while until
the set temperature has been
reached.
The icon “--”
is lit up and
flashing in the
temperature
display.
The display temperature is out of range.
Only temperatures within the range
0~99°F/-9~37°C can be displayed. If
the temperature is not within this
range, the icon “--” will be displayed
instead. This is normal.
Loading ...