4-16
E
EJU00566a
Intermediate housing
Using a grease gun, fill the intermediate
housing with water resistant grease through
the grease nipple 1.
Grease capacity:
Initial 10 hours or 1 month:
33.0–35.0 cm
3
(1.11–1.18 oz)
Every 100 hours or 6 months:
6.0–8.0 cm
3
(0.20–0.27 oz)
EJU00570
Adjusting the choke cable
Check that the choke cable is properly
adjusted.
1. Pull the choke knob out until it stops, and
then release the knob. The knob should
not move.
2. If the choke knob moves back on its own,
tighten the choke knob adjusting nut 1
slightly. If the knob is difficult to move,
loosen the adjusting nut slightly.