Loading ...
Loading ...
Loading ...
Instructions for the installer
5.3 Adjustment for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for LPG, perform the same operations described in paragraph
“5.2 Adjustment for LPG”, but refer to the following table for the proper
injectors.
NG – 1.0 kPa
Burner (*)
Nominal gas
consumption
(MJ/h)
Injector
(mm)
Auxiliary (1) 4.8 0.98
Semi rapid (2) 6.0 1.10
Rapid (6) 11.5 1.50
Rapid (3) 12.2 1.55
Wok (4) 15.0 1.70
Wok (dual control) (5) 15.0 -
Outer 11.5 1.50
Inner 3.5 0.85
(*) For burner reference numbers, see page 15.
6. FINAL OPERATIONS
Having carried out the above adjustments, reassemble the appliance
following, backwards, the instructions in paragraph “5.1 Removing the
hob”.
6.1 Adjustment of minimum for natural gas
Light the burner and take it to the minimum .
Remove the gas tap knob and turn the
adjustment screw inside or at the side of the tap
shaft (depending on the model) until there is a
regular minimum flame. Replace the knob and
check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the
flame should not go out). Repeat the operation on
all the gas taps.
14
Loading ...
Loading ...