User Manual GE AHC18DYL1 ENERGY STAR 230 Volt Electronic Room Air Conditioner

GE AHC18DYL1 ENERGY STAR 230 Volt Electronic Room Air Conditioner - Use Manual - Use Guide PDF.
Documents: Go to download!
  • Owner's manual - (English, Spanish)



User manual Air Conditioner

USING THE AIR CONDITIONER

Controls

Features and appearance will vary.

Lights below the touch pads on the air conditioner control panel indicate the selected settings.

1 Power Pad: Turns air conditioner on and off. When turned on, the display will show the room temperature.

2 Display: Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Heat, Cool or ECO modes.

3 Temp Increase + /Decrease – Pads

  • Use to set temperature when in Heat, Cool or ECO mode. The Set light will turn on while setting.
  • Delay Increase + /Decrease – Pads: Each touch of the Increase + / Decrease - pads on the unit or the Increase + / Decrease – pads on the remote control will set the delay time when using the Delay 1–24hr timer. The Set light will turn on while setting.

4 Fan Speed Pads: Use to set the fan speed to Low, Med, High or Auto on the unit. NOTE: On the remote control, use the fan speed Increase + / Decrease – pads to set the fan speeds to Low, Med or High8VHWKH Auto pad to turn Auto fan on.

5 Mode Pad: Use to set the air conditioner to Heat, Cool, ECO or Fan Only mode.

6. WiFI: Enables connection of the air conditioner to the home WiFi. Download App for details at GEAppliances.com/ connect.

7 Filter Reset Pad LED will turn on when fan has accumulated 250 hours of run time as a reminder to clean filter. Press Reset Filter to turn off the LED and reset the accumulated run time.

8 Control Display On and Off

  • To reduce brightness during sleeping hours, this air conditioner control display has an automatic off feature where the control display will turn off completely after 5 minutes of inactivity. To illuminate the control interface, press any button on the control display or remote control. The control display will illuminate all previously illuminated LED’s. The control interface will now respond to any prescribed button press after it is illuminated.
  • Press and hold the FAN+MODE buttons simultaneously to toggle this feature ON or OFF. The LED’s will now stay ON anytime the unit is ON.

9 Control sound on/off

  • This air conditioner will make a beep when the buttons on the control are pushed or if the unit receives a command from the mobile app or remote control. To silence these beeps, simultaneously press the FAN and “-” buttons for 3 seconds. Press these buttons again to toggle the sound back on.

Do Not Operate in Freezing Outdoor Conditions: This cool-only air conditioner was not designed for freezing outdoor conditions. It must not be used when the outdoor temperature is below freezing (32°F).

Remote Control

  • To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.
  • Make sure nothing is between the air conditioner and the remote control that could block the signal.
  • The remote control signal has a range of up to 20 feet.
  • Make sure batteries are fresh and installed correctly as indicated on the remote control.
  • Remotes contains a magnet allowing it to attach to metal surfaces

Cool Mode

  • Use the Cool Mode at Low, Med, High or Auto fan Speed for cooling. Use the temperature Increase + / Decrease - pads to set the desired temperature between 64°F and 86°F in 1°F increments.
  • An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.
  • NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.
  • Cooling Descriptions
    • For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.
    • For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.
    • For Quieter and Nighttime Cooling—Select the Cool mode and Low fan with a middle set temperature.

ECO Mode

  • This mode optimizes the cooling power of your air conditioner, thereby saving you energy. Once the set point temperature has been reached, the fan will cycle off to save energy. The fan will cycle back on periodically to insure all cooling capacity in the system is used. This mode is the default mode for the unit. Each time the unit is powered off, it will restart in ECO mode ON. This includes Delay timer mode. The first time the unit is turned on, the settings will be 70° and Low fan. You can adjust the fan speed and temperature to your personal comfort.
  • ON—The fan will cycle on and off with the compressor. This may result in wider variations of room temperature and humidity. NOTE: the fan may continue to run for a short time or may pulse intermittently after the compressor cycles off to sample the room air.
  • OFF—The fan runs all the time, while the compressor cycles on and off.

Fan Only Mode

  • Use the Fan Only Mode at Low, Med, High or Auto fan Speed to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.
  • NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode

Auto Fan Mode

  • Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature.
  • If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.
  • NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.

Control Display On and Off

  • To reduce brightness during sleeping hours, this air conditioner control display has an automatic off feature where the control display will turn off completely after 2 minute of inactivity. To illuminate the control interface, press any button on the control display or remote control. The control display will illuminate all previously illuminated LED’s. The control interface will now respond to any prescribed button press after it is illuminated.

Power Outage Recovery

  • Feature In the case of a power outage or interruption, the unit will automatically restart in the settings last used after the power is restored. If the Delay 1–24hr feature was set, it will resume countdown. You may need to set a new time if desired.

Air Direction

  • Use the lever to adjust the air direction left and right only

Care and Cleaning

Grille and Case

  • Turn the air conditioner off and remove the plug from the wall outlet before cleaning.
  • To clean, use water and a mild detergent. Do not use bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

  • Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.
  • Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.
  • DO NOT operate the air conditioner without a filter

CAUTION: because dirt and lint will clog it and reduce performance.

Outdoor Coils

  • The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

How to Insert the Battery in the Remote Control

  1. Remove the battery cover by sliding it according to the arrow direction.
  2. Insert new batteries, making sure that the (+) and (–) of battery are installed correctly.
  3. Reattach the cover by sliding it back into position.

TROUBLESHOOTING TIPS

Troubleshooting Tips... Before you call for service

Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem Possible Causes What To Do
Air conditioner does not start

The air conditioner is unplugged.

The fuse is blown/curcuit breaker is tripped.

Power failure.

The current interrupter device is tripped.

Make sure the air conditioner plug is pushed completely into the outlet.

Check the house fuse/ circuit breaker bos and replace the fuse or reset the breaker.

The unit will automatically restart in the settings last used after the power is restored. There is protective time delay ( approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on.

Press the RESET button located on the power cord plug. If the RESET button will not sta engaged, discontinue use of the air conditioner and contact a qualified service technician.

Air conditioner does not cool as it should

Airflow is restricted.

The temp control may not be set correctly.

The air filter is dirty.

The room may not have been not.

Cold air is escaping

Cooling coils have iced up

Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner

In the Cool mode, press the decrease pad.

Clean the filter at least every 30 days. See the Care and Cleaning section.

When the air conditioner is first turned on, you need to allow time for the room to cool down.

Check for open furnice registers and cold air returns.

See “Air conditioner freezing up” below.

Air conditioner freezing up Ice blocks the air flow and stops the air conditioner from cooling the room. Set the controls at High Fan or High Cool and set the thermostat to a higher temperature.
The remote control is not working

The batteries are inserted incorrectly.

The batteries may be dead

Check the position of the batteries. They should be inserted in the opposite (+) and (–) direction.

Replace the batteries

Water drips outside Hot, humid weather. This is normal.
Water drips indoors The air conditioner is not tilted to the outsides For proper water disposal, make sure the air conditioner slants slightly from the case front to the rear
Water collects in base pan Moisture removed from the air and drains into base pan. This is normal for a short period in areas with little humidity; noirmal for a longer period in very humid areas.

Normal Operating Sounds

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
  • The fan may run even when the compressor does not.


See other models: GSE23GSKKCSS JKP28BF1BB JGB915SEF2SS GTH18ISDBRSS PSI23SCRASV

GE - General Electric AHC18DYL1 | File type: PDF | Filename: aec18dyl1.pdf | Size: 1.8 MB | Language: English, Spanish

Download User Manual

Product Infomation and Reviews - AHC18DYL1 photo

AHC18DYL1 Photo

GE - General Electric in United States

1-800-432-2737 Monday - Friday: 7 a.m. - 10 p.m. ET Saturday - Sunday: 8 a.m. - 6 p.m. E