Basic operation en
7
Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
1. Press ⁠ repeatedly until LED4 lights up in the LED
display for intensive mode1.
2. Press ⁠ repeatedly until LED5 lights up in the LED
display for intensive mode2.
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
Switching off intensive mode
To select a fan setting of your choice, press ⁠ .
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
Switching on the fan run-on
Press ⁠ .
a LED1 for the fan setting lights up in the LED dis-
play. LED6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
Switching off the fan run-on
Press ⁠ .
a This immediately stops the fan run-on.
a The appliance switches to the fan setting that was
previously selected.
Switch on automatic mode
1
The optimum fan setting is set automatically using a
sensor.
Press ⁠ .
a In the LED display, LED6 lights up for automatic
mode.
Switch off automatic mode
1
Press ⁠ .
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note:This function is only available via a mobile device
with the
HomeConnect
app.
If the interval ventilation is switched on, LED6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED6 contin-
ues to flash.
Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting3
¡ Lowest setting: Fan setting1
¡ Highest setting: Fan setting5
Setting the sensor control
Requirement:The appliance is switched off.
1. Press and hold ⁠ and ⁠ for approx.three seconds.
2. Press ⁠ or⁠ to change the setting.
To cancel the setting, press⁠ .
3. To save the setting, press and hold ⁠ and⁠ for ap-
prox. threeseconds.
Or wait approx. 10seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched off.
1. Press and hold ⁠ and ⁠ for approx.three seconds.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠ /⁠ until LED2 lights up in the LED
display.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠ /⁠ until LED3 lights up in the LED
display.
To convert the electronic control back to opera-
tion without the air recirculation filter, press ⁠ /⁠
until LED1 lights up on the LED display.
2. To save the setting, press and hold⁠ and⁠ for ap-
prox. three seconds.
Or wait approx. 10seconds until the setting is
saved automatically.
To cancel the setting, press⁠ .
a A signal tone sounds as soon as the selected set-
ting is saved.
Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off, LED1
flashes in the LED display for the grease filter satura-
tion display and/or LED2 flashes for the saturation
indicator for the odour filter.
¡ A repeated signal tone sounds.
Press ⁠ .
a The saturation indicator is reset.